Checking
- Make
- SEAT
- Model
- Exeo
- Year
- 2008–2013
- Section
- Heating, air conditioning › Checking
Checking
Measure the ambient temperature (must be greater than 15°C).
Close doors, bonnet, windows and sunroof.
Open all dash panel vents.
Switch on ignition.
Set “Econ” mode on operating and display unit, Climatronic control unit J255 (lamp in Econ button lights).
Start the engine.
Start air conditioner self-diagnosis.
Select display group “001” in “Reading measured value block” function.
Check the display in the display zones:
Display zone “2” shows 0 % (compressor off).
Display zone “4” indicates that the pressure in the refrigerant circuit at the measured ambient temperature is equal to or greater than the value in the table.
| Ambient temperature in °C | Displayed pressure (in bar absolute) |
|---|---|
| 15 | 4,7 |
| 20 | 5,6 |
| 25 | 6,6 |
| 30 | 7,6 |
| 35 | 8,8 |
Note
- corresponds to an absolute vacuum. Normal ambient pressure thus corresponds to roughly absolute. On the scales of most pressure gauges, corresponds to an absolute pressure of one bar (can be seen from mark below ).
- Pressure in refrigerant circuit depends on atmospheric temperature. Due to the radiation of heat by components (e.g. the radiator fan), the pressure displayed with a warm engine is slightly higher than that given for the corresponding ambient temperature.
- high-pressure sender G65 and . If no fault is found at the high-pressure sender, there is not enough refrigerant in the circuit and the vehicle must be taken to a specialist air conditioner workshop.
If the pressure in the refrigerant circuit is OK
Switch on compressor by selecting “Auto” mode on operating and display unit, Climatronic control unit J255 (lamp in Econ button does not light).
Set “Lo” temperature setting (for driver's and front passenger's side) on operating and display unit (Climatronic control unit J255).
Set air outflow direction on operating and display unit, Climatronic control unit J255 to “dash panel vents”.
Select display group “001” in “Reading measured value block” function.
Check the display in the display zones:
Display zone “2” shows a duty cycle of greater than 30 % (actuation of the air conditioning system compressor regulating valve N280, the compressor is switched on)
Display zone “1” shows a current of greater than 0.3 A (current flowing via the air conditioning system compressor regulating valve N280, the compressor is switched on)
Pressure displayed in zone “4” rises above value when compressor is switched off.
Note
- air conditioning system compressor regulating valve N280 is actuated by the operating and display unit, Climatronic control unit J255 such that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 5°). 2 to 5° C): After the vehicle starts, a value greater than 75 % (0,55 A) is displayed independent of the temperature, engine revolutions and the on-board voltage measured. As soon as the temperature measured by the evaporator outflow temperature sender G263 approaches the specified value, actuation is cancelled and the compressor output thus reduced.
- Under certain operating conditions, residual moisture in refrigerant circuit may cause ice to form at compressor regulating valve. Such ice formation impedes compressor control. The evaporator is cooled excessively and ices up. Icing-up of the evaporator may give rise to the following problems
- - Repeated or sporadic failure of air conditioner (no cooling/heat output) after a long journey; air conditioner functions properly again after a short delay following engine shutoff.
- button; air conditioner functions properly again after a short delay following engine shutoff.
- Remedy:
- evaporator outlet temperature sender G263).
- evaporator outlet temperature sender G263 (the evaporator may ice-up resulting from an incorrect value).
- air conditioning system compressor regulating valve N280 is not currently being actuated, the vehicle is to be taken to a specialist air conditioner workshop.
- - Check refrigerant pipe between evaporator and reservoir (thick pipe, low-pressure end) with engine running. If pipe is severely iced up when problem occurs (thin ice layer is permissible), this is a further indication that the temperature in the evaporator is too low.
- - Make the specialist air conditioner workshop aware of any problem encountered. The necessary work can only be performed by such specialists (discharging of refrigerant circuit, replacement of reservoir and subsequent evacuation of refrigerant circuit for at least 3 hours).
- shows no or insufficient current, check actuation of air conditioning system compressor regulating valve N280.
- does not vary and the compressor controlling is correct (display field and ), this indicates a fault in the refrigerant circuit. Visit a specialist air conditioner workshop.
Press recirculated-air flap button (“recirculated-air mode” symbol in button lights).
Set engine speed to 2000 rpm (start of time measurement).
Select display group “010” in “Reading measured value block” function.
Compare the measured value indicated in display zone “1” (for the evaporator outlet temperature sender G263) to the values in the graph.

Depending on ambient temperature, the measured air temperature must be within the stated tolerance range after 5 minutes.
Note
- evaporator outflow temperature sender G263. Compare measured values shown in display groups , zone and , zones and :
- or only differs slightly from the measured value in display group , Perform "Measures to be taken if readout does not match specification" Chapter “Fault Finding if readout does not match specification”
- evaporator outlet temperature sender G263 is greater than the measurement value of the outlet temperature sender, left side G150 and outlet temperature sender, right side G151, check the evaporator outlet temperature sender G263 that it is installed correctly and carry out the electric test for this sensor .
- (thick pipe).
The measurement value of the evaporator outlet temperature sender G263 (and therefore the cooling output of air conditioner) is OK.
Compare measured values shown in display “1” of the measurement values displayed in the display group “010” (the evaporator outlet temperature sender G263) with the measurement values displayed in the display group “009” Display field “3” and “4” (left outlet temperature sender G150 and right outlet temperature sender G151).
The measurement values in the display group “009” Display field “3” and “4” (left outlet temperature sender G150 and right outlet temperature sender G151) is allowed to be maximum 3° C than the value in the display field after 5 minutes “1” of the display group “010” (of the evaporator outlet temperature sender G263).
Note
- , display zones and :
- or ,`check if the actuator motor of the temperature flap where, the measurement value is not O.K (left temperature flap control motor V158 or right temperature flap control motor V159) and carry out the electric test for the sensor left outlet temperature sender G150 and right outlet temperature sender G151 by .
- or of display group is lower than that in display zones of display group , Check if the evaporator outlet temperature sender G263, left outlet temperature sender G150 and right outlet temperature sender G151 have been installed correctly and their electrical connections for contact resistance, replace the defective sensor if necessary.
- left outlet temperature sender G150 or on the right outlet temperature sender G151 as well as on the left temperature flap servomotor V158 or on the right temperature flap servomotor V159, with temperature rises, carry out the troubleshooting after the evaporator Chapter “Fault Finding if temperature increases downstream of evaporator”.
- dash panel vents can additionally be measured for example using the Minitester V.A.G 1362 (or a commercially available thermometer).
- , the measurement value of the air temperature sender, left foot well zone vent G261 and the air temperature sender, right foot well zone vent G262 are displayed in the display fields and . As the air flow in mode is only routed to the dash panel vents, these two senders indicate an imprecise value in this setting. Pressing the button makes it possible to incorporate these senders into the test as well.
Parts & tools for this job For 2008 SEAT Exeo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Exeo 2008 cabin filter
As an Amazon Associate we earn from qualifying purchases.