Detaching and attaching refrigerant lines at condenser
- Venting device for the air conditioner SAT 4006D

- Torque wrench kit SAT 8010

Discharge refrigerant circuit Air conditioner with refrigerant R134a.
Remove noise insulation General body repairs, exterior Rep. gr. 50.
Remove the front bumper completely General Body Repairs, Exterior Rep. gr. 63
Unscrew bolts (A).

Detach refrigerant pipes from condenser.
Note
- Seal open pipes and the connections at the condenser with suitable caps (to prevent the ingress of dirt and moisture).
Attach in reverse order; note the following:
Check type of seal at connections and refrigerant pipes (must be designed for same type of seal) Chapter “Refrigerant pipe connections at components (different versions)” and Parts List
Replace O-rings (B) and (C); for version refer to Spare parts catalogue

Secure the refrigerant lines with the screws (A) (tightening torque 9 Nm).
Check the routing of the lines (A). They must be attached to the brackets provided for this purpose (B), and may not come into contact with any other component.

Charging the refrigerant circuit. Air conditioner with refrigerant R134a