01 Power transmission02 Running gear03 Body04 Power tramsmission05 Power unit06 Vehicle electrics07 Heating-ventilation-air conditioning system08 Automatic gearbox09 Engine, mixture preparation10 Engine, mechanics11 Manual gearbox12 Running gear - self diagnosis13 Heating and air conditioning14 Bodywork15 Heating, ventilation, air conditioning system
SEAT Leon Mk102 · Running gear
02 · Steering & suspension

Pressure leak test

Make
SEAT
Model
Leon Mk1
Section
Brake systems › Brakes, hydraulics, regulator, servo › Pressure leak test
Running gearPressure leak test
Test prerequisites
Brake system (hydraulic unit, brake hoses, brake pipes and brake calipers) operating properly and free of leaks.
–  Remove bleed valve at one of front brake calipers. Connect and bleed gauge from tester for brake pressure regulator -V.A.G 1310 A-.
–  Apply pressure to brake pedal until the gauge indicates a pressure of 50 bar. The pressure must not drop by more than 4 bar during the test period of 45 seconds. Renew brake master cylinder if pressure drops greatly.
   