Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Toledo (5P, 2004-2009)44 · Air conditioner
44 · Heating & A/C

Check refrigerating output

Make
SEAT
Model
Toledo
Year
5P, 2004–2009
Section
Heating and air conditioning › Check refrigerating output
Air conditionerCheck refrigerating output

Check refrigerating output

Heating, ventilation, air conditioning system · Heating and air conditioning · Refrigeration performance of the air conditioning: testing · Altea, Toledo from 2005 · Edition 12.2010

Measure the ambient temperature (must be greater than 15℃).

Close doors, bonnet, windows and sun roof.

Open all dash panel vents.

Switch on the ignition.

Vehicles fitted with Climatronic:

Select the „Econ“ mode on the Climatronic control unit J255.

Vehicles fitted with Climatic:

The button „AC“ should not be activated.

Start engine.

Finish the air conditioning self-diagnosis Vehicle diagnostic, testing and information system VAS 5051.

Select the function „ Read measurement value block“. Check the corresponding measurement value blocks for the refrigerant circuit pressure Vehicle diagnostic, testing and information system VAS 5051.

Check the indication in the display fields:

Ambient temperature in °CDisplayed pressure (in bar absolute)
154,7
205,6
256,6
307,6
358,8

Note

  • An absolute pressure of 0 bar represents an absolute vacuum. The normal ambient pressure is therefore equivalent to approx. 1 bar absolute pressure. In general most manometer scales represent atmospheric pressure as 0 bar meaning an absolute pressure of 1 bar (this can be recognised if there is a -1 on the scale).
  • Pressure in refrigerant circuit depends on atmospheric temperature. Due to heat radiation from components (for example the coolant radiator), for a warm engine at normal running temperature, the indicated pressure is a above the corresponding atmospheric temperature.
  • If the displayed pressure is lower than that given in the table:
  • High pressure sender G65Chapter “Checking the pressure signal of the High pressure sender G65.”.
  • If no fault is found at high-pressure sender, there is not enough refrigerant in the circuit and vehicle must be taken to a specialist air conditioner workshop.

If pressure in refrigerant circuit is OK.

Vehicles fitted with Climatronic:

Switch on the compressor by adjusting the operating mode „Auto“ on the Climatronic control unit J255.

Select the lowest temperature setting (for driver and passenger side) on the Climatronic control unit J255.

Adjust air outlet direction on the Climatronic control unit J255 to the „dashboard vents“.

Vehicles fitted with Climatic:

With the button „AC“ pressed, the speed „1“ of the Fresh air blower V2 is selected along with the lowest possible temperature.

Adjust air direction to the „instrument panel vents“

All vehicles (continued):

Select the function „ Read measurement value block“Vehicle diagnostic, testing and information system VAS 5051.

Check in the corresponding indication fields for a duty cycle of more than 30 % (the Compressor regulation valve, air conditioning N280 is activated, the compressor is running), and a current intensity of more than 0.3 A (current flows through the Compressor regulation valve, air conditioning N280, the compressor is operating)

Pressure in the refrigeration circuit rises above value with compressor off.

Note

  • Compressor regulation valve, air conditioning N280 is operated by the Climatronic control unit J255/Air conditioning control unit J301 in such a way that the air temperature reaches the specified value (approx. 2 to 5℃) after the evaporator:
  • After starting the vehicle, a value greater than 75 % (0.55 A) is displayed depending on the measured temperature, engine speed and electrical system voltage.
  • Air temperature sender, evaporator output G263 approaches the specification, the activation is reduced as is the compressor performance.
  • Under certain conditions of use, ice may form on the regulation valve for the compressor (and on the expansion valve) because of humidity on the refrigeration circuit. Due to the formation of this ice, the regulation of the compressor is inhibited, the evaporator is cooled too much and will freeze. Freezing of the evaporator can lead to the following complaints:
  • After a longer driving period, the air conditioner fails several times or every now and then (no cooling or heating performance). The function of the air conditioner is okay again after turning off the vehicle and after a brief waiting time.
  • button does not free the windows from the mist. The function of the air conditioner is okay again after turning off the vehicle and after a brief waiting time.
  • Remedy
  • Air temperature sender, evaporator G263 function
    Vehicle diagnostic, testing and information system VAS 5051.
  • Air temperature sender, evaporator output G263 (the evaporator may freeze because of a measurement value error).
  • If the measurement value of the sender is very low under the conditions described by the client (with an atmospheric temperature of more than 0℃, less than 0° for a long time), bring the vehicle to a workshop specialised in air conditioning.
  • Check the refrigeration tubes from the evaporator (from the expansion valve) to the compressor (thick tube, low pressure side) while the engine is running. If the pipe is severely iced up by the problem described (thin ice layer is permissible), this is a further indication that the temperature in the evaporator is too low. Bring the vehicle to a workshop specialised in air conditioning.
  • The specialist workshop can determine the error. The required work (draining the refrigerant circuit, replacing tanks and then allow the refrigerant circuit to drain for minimum 3 hours) can only be carried out by such specialist workshops.
  • Compressor regulation valve, air conditioning N280Chapter “Check the activation signal for the Compressor regulation valve, air conditioning N280”.
  • When the pressure displayed in the respective measured value block does not change and the controlling of the compressors is okay, there is a fault in the refrigerant line Bring the vehicle to a workshop specialised in air conditioning.

Press the button for air recirculation on the Climatronic control unit J255/Air conditioning control unit J301 (the symbol for the „air recirculation mode“ lights).

Bring the engine speed up to 2.000 rpm (begin timing).

Select the function „Read measurement block values“ for the indication group corresponding to the Air temperature sender, evaporator G263.

Compare measured value indicated in display field (of the Air temperature sender, evaporator output G263) to values in the diagram.

A87-0373
A Air temperature measured by the air temperature sender, evaporator G263 B Ambient temperature C Acceptable tolerance range

The measured air temperature must be within the tolerance range shown for 5 minutes depending on the atmospheric temperature.

Note

  • Air temperature sender, evaporator G263, compare the measurement values in the corresponding indication fields:
  • evaporator outlet temperature sender G263 is greater than the measurement value of the left outlet temperature sender G150 and des right outlet temperature sender G151 (Climatic: Centre outlet temperature sender G191), check the correct fitting of the evaporator outlet temperature sender G263 and perform the electrical inspection of this sender Vehicle diagnostic, testing and information system VAS 5051.
  • The operation of the air conditioning can be seen for example by the cooling of the rigid refrigerant tube on the low pressure side (thick tube).

If the measurement value of the Air temperature sender, evaporator G263 (and, with this, the refrigeration power) are correct:

Compare the measurement value of the evaporator outlet temperature sender G263 with the measurement value of the left outlet temperature sender G150 and des right outlet temperature sender G151 (Climatic: Air temperature sender, central vent G191).

The measurement value of the left outlet temperature sender G150 and the right outlet temperature sender G151 (Climatic: Air temperature sender, central vent G191) are only allowed to be max. 3°C higher than the value in the displayed field of the evaporator outlet temperature sender G263 after 5 minutes.

Note

  • If the required values are not reached, compare the measurement values to each other:
  • left temperature flap servomotor V158 and the right temperature flap servomotor V159. (Climatic: temperature flap control motor V68) Chapter “Locating faults in case of an increase in temperature after the evaporator”, Chapter “Check the heating performance of the air conditioning” and Vehicle diagnostic, testing and information system VAS 5051
  • evaporator outlet temperature sender G263, the left outlet temperature sender G150 and the right outlet temperature sender G151 (Climatic: Air temperature sender, central vent G191) and if their electrical connections have contact resistance. If necessary, replace a defective sender.Vehicle diagnostic, testing and information system VAS 5051
  • left outlet temperature sender G150 nor the right outlet temperature sender G151 (Climatic: Air temperature sender, central vent G191 nor the left temperature flap control motor V158 and right temperature flap control motor V159 (Climatic: temperature flap control motor V68, perform the troubleshooting after increasing the temperature after the evaporator Chapter “Locating faults in case of an increase in temperature after the evaporator”.
  • instrument panel vents can also be measured using a normal thermometer for example.
  • If the client complains of different temperatures for the same settings, this could be due to the following:
  • Chapter “Air intake, air outlet and air flow in the air conditioning” and Vehicle diagnostic, testing and information system VAS 5051.
  • Chapter “Check the heating performance of the air conditioning”.
  • When fitting the heat exchanger, a sponge seal has been displaced and the air passes around the heat exchanger.

Parts & tools for this job For 2004 SEAT Toledo