Removing
Remove the glove compartment Bodywork, interior fitting work Rep. Gr. 68.
Remove the passenger side foot well cover Bodywork, interior fitting work Rep. Gr. 68.
Remove the bolt (A).

Cut the cable ties to those fitted in the fresh air turbine housing cables (C).
Release the block (B) and rotate the fresh air turbine housing (C) in (the direction of the arrow).
Note!
- (C) and the heating system may be sealed by a sealing paste, in which case it will be necessary to rotate the housing with more force.
- (C) the Fresh air turbine (01273-4124) V2 and the Fresh air turbine control unit J126 are fitted and cannot be replaced separately Parts catalogue.

Remove the fresh air turbine housing (C) from the air conditioning.
Disconnect the connector (D).