01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Toledo (5P, 2004-2009)44 · Air conditioner
44 · Heating & A/C

Coolant agent R134a

Make
SEAT
Model
Toledo
Year
5P, 2004–2009
Section
Heating and air conditioning › Coolant agent R134a
Air conditionerCoolant agent R134a

Coolant agent R134a

Heating, ventilation, air conditioning system · Heating and air conditioning · Capacity · Ibiza from 2002 · Edition 02.2008

Filling quantities for refrigerant R134a and oil for refrigeration units:

Air conditioning - with refrigerant R134a

Note

  • Always fill the refrigerant circuit up to the upper tolerance limit (there is refrigerant in the filling hoses).
  • Parts catalogue
  • Air conditioning - with refrigerant R134a
  • G 052 300 A2Parts catalogueAir conditioning - with refrigerant R134a.
  • The oil for refrigeration units coming from containers that have been open for a relatively long time are rendered useless (PAG oil absorbs moisture) and should not be used.
  • Air conditioning - with refrigerant R134a
CompressorManufacturerCapacity
6SEU12C
6SEU14C
7SEU16C
Denso
Denso
Denso
550 ± 25 grams
550 ± 25 grams
550 ± 25 grams