Installing
- Make
- SEAT
- Model
- Toledo
- Year
- 5P, 2004–2009
- Section
- Heating and air conditioning › Installing
‹ Prev Refrigerant lines, expansion valve: Removing and installingNext › Removing and fitting the expansion valve
Air conditionerInstalling
Installing
Installation is carried out in the reverse sequence; note the following:
Replace all O-ring seals (D) and (E). Version Parts catalogue.

Check the fastener (G) (Fitted to the junction or expansion valve, not fitted to all junctions) and the sleeve (H) for correct seating and damage.
Note
- Chapter “O-rings for refrigerant circuit”.
- (F) in the tubes of the refrigerant agent.
- Install refrigerant pipes such that they are not strained.
- Depending on the vehicle equipment and the engine fitted, thermal insulation is fitted to the coolant tubes, which should not be damaged and should be re-installed after fitting
- Check the fitting position of the coolant tubes to the expansion valve (should not be supported by other parts) and check the position and condition of other thermal insulation if existing on the coolant tubes (certain engines do not require them).
‹ Prev Refrigerant lines, expansion valve: Removing and installingNext › Removing and fitting the expansion valve
Parts & tools for this job For 2004 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 2004 cabin filter