Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Toledo (5P, 2004-2009)44 · Air conditioner
44 · Heating & A/C

Cooling power: checking

Make
SEAT
Model
Toledo
Year
5P, 2004–2009
Section
Heating and air conditioning › Cooling power: checking
Air conditionerCooling power: checking

Cooling power: checking

Heating, ventilation, air conditioning system · Heating and air conditioning · Refrigeration performance of the air conditioning: check · Toledo from 2005 · Edition 07.2007

Measure ambient temperature (must be greater than 15°C).

Close doors, bonnet, windows and sun roof.

Open all dashboard vents.

Switch on ignition.

Vehicles fitted with Climatronic:

Select the “Econ” mode on the Climatronic control unit J255.

Vehicles fitted with Climatic:

The button “AC” should not be activated.

Start engine.

Finish the climate control self-diagnosis Vehicle diagnosis, testing and information system VAS 5051

Select the function “ Read measurement value block”. Check the corresponding measurement value blocks for the refrigerant circuit pressure Vehicle diagnosis, testing and information system VAS 5051.

Check the indication in the display fields:

Atmospheric temperature °CIndicated pressure (bar of absolute pressure)
154,7
205,6
256,6
307,6
358,8

Note

  • In absolute pressure 0 bar means a vacuum. The normal atmospheric temperature is, thus, about 1 bar of absolute pressure. In general most manometer scales represent atmospheric pressure as 0 bar meaning an absolute pressure of 1 bar (this can be recognised if there is a -1 on the scale).
  • Pressure in refrigerant circuit depends on atmospheric temperature. Due to heat radiation from components (for example the coolant radiator), for a warm engine at normal running temperature, the indicated pressure is a above the corresponding atmospheric temperature.
  • If the pressure indicated is less than indicated in the table:
  • High pressure sender G65Chapter “Checking the pressure signal of the High pressure sender G65.”
  • If no fault is found at high-pressure sender, there is not enough refrigerant in the circuit and vehicle must be taken to a specialist air conditioner workshop.

If pressure in refrigerant circuit is OK.

Vehicles fitted with Climatronic:

Switch on the compressor by adjusting the operating mode “Auto” on the Climatronic control unit J255.

Select the lowest temperature setting (for driver and passenger side) on the Climatronic control unit J255.

Adjust air outlet direction on the Climatronic control unit J255 to the “dashboard vents”.

Vehicles fitted with Climatic:

With the button “AC” pressed, the speed “1” of the Fresh air turbine V2 is selected along with the lowest possible temperature.

Adjust air direction to the “dashboard vents” positions

Continued for all vehicles:

Select the function “ Read measurement value block” Vehicle diagnosis, testing and information system VAS 5051.

Check in the corresponding indication fields for a duty cycle of more than 30% (the Compressor regulation valve, air conditioning N280 is activated, the compressor is running), and a current intensity of more than 0.3 A (current flows through the Compressor regulation valve, air conditioning N280, the compressor is operating)

Pressure in the refrigeration circuit rises above value with compressor off.

Note

  • Compressor regulation valve, air conditioning N280 is operated by the Climatronic control unit J255/Air conditioning control unit J301, so that the air temperature at the evaporator output reaches the specified temperature (about 2 to 5°C):
  • After starting the vehicle, depending on the measured temperature, the engine speed and the onboard voltage, a value of more than 75% (0.55A) may be recorded.
  • Air temperature sender, evaporator output G263 approaches the specification, the activation is reduced as is the compressor performance.
  • Under certain conditions of use, ice may form on the regulation valve for the compressor (and on the expansion valve) because of humidity on the refrigeration circuit. Due to the formation of this ice, the regulation of the compressor is inhibited, the evaporator is cooled too much and will freeze. Freezing of the evaporator can lead to the following complaints:
  • During a long journey, the air conditioning stops working several times sporadically (no cooling or heating effect); after turning the vehicle off and waiting for a period the air conditioning returns to normal.
  • button the window remain fogged up; after turning the vehicle off and waiting for a period the air conditioning returns to normal.
  • Remedy
  • Air temperature sender, evaporator output G263 function
    Vehicle diagnosis, testing and information system VAS 5051.
  • Air temperature sender, evaporator output G263 (the evaporator may freeze because of a measurement value error).
  • If the measurement value of the sender is very low under the conditions described by the client (with an atmospheric temperature of more than 0°C, less than 0° for a long time), bring the vehicle to a workshop specialised in air conditioning.
  • Check the refrigeration tubes from the evaporator (from the expansion valve) to the compressor (thick tube, low pressure side) while the engine is running. If, during the reported incident the tube is quite frozen (a thin layer of ice is acceptable) this means that the temperature in the evaporator is too low; bring the vehicle to a workshop specialised in air conditioning.
  • Describe the fault detected to the workshop personnel; the required work may only be carried out there (emptying of the refrigeration circuit, replacement of the tank and, then, evacuation of the circuit for at least three hours).
  • Compressor regulation valve, air conditioning N280Chapter “Check the activation signal for the Compressor regulation valve, air conditioning N280”.
  • If the pressure displayed in the measurement values block does not change and the activation of the compressor is correct, there is an error in the refrigeration circuit; bring the vehicle to a workshop specialised in air conditioning.

Press the button for air recirculation on the Climatronic control unit J255/Air conditioning control unit J301 (the symbol for the “air recirculation mode” lights).

Bring the engine speed up to 2.000 rpm (begin timing).

Select the function “Read measurement block values” for the indication group corresponding to the Air temperature sender, evaporator output G263.

Compare measured value indicated in display field (of the Air temperature sender, evaporator output G263) to values in the diagram.

A87-0373
A Air temperature measured by the Air temperature sender, evaporator output G263 B Ambient temperature C Acceptable tolerance range

The measured air temperature must be within the tolerance range shown for 5 minutes depending on the atmospheric temperature.

Note

  • Air temperature sender, evaporator output G263, compare the measurement values in the corresponding indication fields:
  • Air temperature sender, evaporator output G263 is greater than the measurement values of the Air temperature sender for the left hand side vent G150 and the Air temperature sender for the right hand side vent G151 (Climatic: Temperature sender, central vent G191), check the Air temperature sender, evaporator outlet G263 to ensure it is correctly fitted and make an electrical check for this senderVehicle diagnosis, testing and information system VAS 5051.
  • The operation of the air conditioning can be seen for example by the cooling of the rigid refrigerant tube on the low pressure side (thick tube).

If the measurement value of the Air temperature sender, evaporator output G263 (and, with this, the refrigeration power) are correct:

Compare the measurement value of the Air temperature sender, evaporator output G263 with the measurement values of the Air temperature sender for the left hand side vent G150 and the Air temperature sender for the right hand side vent G151 (Climatic: Temperature sender, central vent G191).

The measurement values of the Air temperature sender for the left hand side vent G150 and the Air temperature sender for the right hand side vent G151 (Climatic: Temperature sender, centre vent G191) after 5 minutes may be a maximum of 3° higher than the value in the display field of the Air temperature sender, evaporator outlet G263.

Note

  • If the required values are not reached, compare the measurement values to each other:
  • Servomotor for the left-hand side temperature flap V158, Servomotor for the right-hand side temperature flap V159 (Climatic: (Climatic: Servomotor for the temperature flap V68)Chapter “Locating faults in case of an increase in temperature after the evaporator”, Chapter “Check the heating performance of the air conditioning” and Vehicle diagnosis, testing and information system VAS 5051
  • Air temperature sender, evaporator output G263, the Air temperature sender for the left hand side vent G150 and the Air temperature sender for the right hand side vent G151 (Climatic: Temperature sender, centre vent G191) are correctly fitted and the electrical connections have contact resistance. If necessary, replace the faulty sender Vehicle diagnosis, testing and information system VAS 5051.
  • Air temperature sender for the left hand side vent G150 and the Air temperature sender for the right hand side vent G151 (Climatic: Temperature sender, centre vent G191 or in the Servomotor for left-hand side temperature flap. V158 and Servomotor for right-hand side temperature flap V159 (Climatic: Servomotor for the temperature flap V68, carry out fault finding increasing the temperature after the evaporator Chapter “Locating faults in case of an increase in temperature after the evaporator”.
  • dashboard vents can also be measured using a normal thermometer for example.
  • If the client complains of different temperatures for the same settings, this could be due to the following:
  • Chapter “Air intake, air outlet and air flow in the air conditioning” and Vehicle diagnosis, testing and information system VAS 5051.
  • Chapter “Check the heating performance of the air conditioning”.
  • When fitting the heat exchanger, a sponge seal has been displaced and the air passes around the heat exchanger.

Parts & tools for this job For 2004 SEAT Toledo