Draining the refrigerant circuit
- Make
- SEAT
- Model
- Toledo
- Year
- 5P, 2004–2009
- Section
- Heating and air conditioning › Draining the refrigerant circuit
Draining the refrigerant circuit
The coolant must not be poured into the environment. It should be removed by suction from the coolant circuit, either with a suction extraction station or with a service station. The suctioned coolant is then prepared on-site and delivered to the manufacturer to be disposed of ecologically (in some countries different regulations may be in force). Therefore, the vehicle should be taken to a workshop specialising in air conditioning systems (these workshops have the relevant equipment and tools).
The refrigerant R134a contributes enormously to the global warming effect if released into the atmosphere.
Note!
- The greenhouse effect of the refrigerating agent R134a is significantly lower than that of the refrigerating agent R12.
- The coolant R134a does not affect the ozone layer of the earth's atmosphere (coolant R134a is a hydrofluorocarbon without chlorine atoms). The destruction of the ozone layer is only produced by the breakdown of carbon and chlorine compounds (as happens for example with coolant R12).
After emptying the air conditioner, separate the connector for the Compressor regulation valve, air conditioning (01232) N280 or of the High pressure sender (00819) G65.
The Compressor regulation valve, air conditioning (01232) N280 is not further activated and the compressor works at idle speed. The compressor is built in such a way to ensure the lubrication of the compressor parts at idle speed by means of an internal oil circuit (as long as there is sufficient coolant oil in the compressor).
Parts & tools for this job For 2004 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 2004 cabin filter