Installing
- Make
- SEAT
- Model
- Toledo
- Year
- 5P, 2004–2009
- Section
- Heating and air conditioning › Installing
Installing
Note!
- position. Only when cogwheel (A) is at the maximum (B), is it possible to fit it onto the cogwheel of the air retention flap. If a servomotor has been removed in a different position or has been activated during removal, it will not be possible to reassemble.

- (A) is not at the limit (B), connect an adapter cable Chapter “Preparing adapter cables for control motor actuation” or an auxiliary cable from the auxiliary measurement set VAG 1594C to the contacts 5 and 6 of the servo motor through a 5 A fuse to a 12 V battery.
The servo motor will move to the limit in one direction; swapping the poles will make it move in the other direction.
Wait until the cogwheel (A) of the servo motor reaches the limit “fresh air option” (B) (see diagram).
Check before trying to fit a new servo motor, the retention flap opening in the air inlet and the cogwheel (C) (the air retention flap is open, fresh air service).

Switch off the ignition.
Connect the Servomotor for the air retention flap (01274-4131) V71 to the cable harness of the vehicle (note the correct allocation of the connectors).
Open the air recirculation flap (E).

Insert a hand into the air inlet opening for the air recirculation and move the air retention flap (A) into the position “fresh air option” (the opening for the air recirculation option is closed).
Fit the servo motor (B) in the opposition direction to the arrow on the allotments (C) and onto the cogwheel (D).

In order to move the cogwheel on the servo motor (A) onto the cogwheel of the air retention flap, the curved teeth (C) of the servo motor cogwheel must coincide with space between the teeth (D) of the cogwheel on the air retention flap axle (B).

Fit the Servomotor for the air recirculation flap (00716) V113 Chapter “Removing and installing fresh air and air recirculation flap control motorV113, vehicles ¶% 05.2008”.
Lay wiring harness so that it cannot come into contact with moving components (e.g. control motor lever).
Fit the support (A), taking into account that the support guide (B) is fitted correctly into the allotment in the air inlet opening (C) and that the support correctly inserts into both slots (D) and (E).

Test both servo motors, the support (A) must hold its position; if there is some play then eliminate it by applying some spongy material to the interior of the attachment points (F) of the support (A)
Note!
- Servomotor for the air retention flap (01274-4131) V71 and the Servomotor for the air recirculation flap (00716) V113 (and the corresponding flaps) are not visible when the glove compartment is fitted, for this reason, operation must be checked before fitting the glove box.
- Servomotor for the air retention flap (01274-4131) V71 and the air retention flap) are assembled incorrectly, the air retention flap will not reach its limits (may be detected using the as a fault) or the servomotor will function incorrectly, unstable operation.
Following fitting the servo motor, carry out a basic setting of the air conditioning and consult the fault memory of the air conditioning Vehicle diagnosis, testing and information system VAS 5051.
Switch ignition on:
Activate the Servomotor for the air retention flap (01274-4131) V71 and the Servomotor for air recirculation flap (00716) V113 with the Climatronic control unit (01320) J255 as described below, until the cogwheel is at its “air recirculation mode” limit (this diagram shows the air retention flap (A) at the “Fresh air mode” limit) and check the position of the air retention flap, this must be closed.

First select the function “air recirculation” in the Climatronic control unit (01320) J255.
The Servomotor for the air recirculation flap (00716) V113 opens the flap (E) and the Servomotor for the air retention flap (01274-4131) V71 puts the air retention flap (A) in the position “air intake for the air recirculation mode”.

Wait until both servo motors have reached their final position.
Select the function “fresh air option” for example in mode “deice” (in this mode, the servo motors will always position themselves in the fresh air mode).
The Servomotor for the air retention flap (01274-4131) V71 puts the air retention flap (A) in the position “air intake for air recirculation closed”, the Servomotor for the air recirculation flap (00716) V113 positions the flap (E) in the position defined by the Climatronic control unit (01320) J255.
Wait until both servo motors have reached their final position.
Re-install all parts removed in reverse order, paying attention to the following:
Note!
- (A) is visible when the air recirculation flap (E) is closed through the air inlet opening in the plenum chamber (remove the plenum chamber cover).
- (A) at high speeds (above approx. 80 km/h) by the Climatronic control unit (01320) J255 (the position of the air recirculation flap (E) is specified by the control and indication panel Climatronic control unit (01320) J255).

- Fresh air turbine (01273-4124) V2 changes due to the different air intake, the activation of the Servomotor for the air retention flap (01274-4131) V71 and the Servomotor for the air recirculation flap (00716) V113 takes place in the following way:
- (E) opens first, next the fresh air flow duct closes using the air retention flap (A).
- (A), next the air recirculation flap closes (E).
- (E) and the Climatronic control unit (01320) J255 set the air retention flap (A) into a central position (the fresh air duct and the air recirculation collection ducts are both slightly open at the same time). This ensures improved cooling at certain temperature ranges and, at the same time, allows a little fresh air to enter.

Parts & tools for this job For 2004 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.