Component extensions „2“
- Make
- SEAT
- Model
- Toledo
- Year
- 5P, 2004–2009
- Section
- Heating and air conditioning › Component extensions „2“
Air conditionerComponent extensions „2“
Component extensions „2“

- 1 Condensation drain
Verification, removing and fitting Chapter “Removing, checking and installing condensation drain hose” - 2 Expansion valve
Removing and refitting the refrigerant tubes Chapter “Refrigerant lines, expansion valve: Removing and installing”
Removing and fitting Chapter “Removing and installing expansion valve” - 3 Radiator fan V7
The request for fan cut-in is transmitted by the Climatronic control unit J255 over the comfort system data bus to engine control unit. The engine control unit then activates the ventilators directly through the Coolant ventilator control unit J293 Engine, mechanics Rep. gr. 19
The corresponding control unit activates, for example, the Coolant ventilator V7 (through the Coolant ventilator control unit J293) according to the power required (and depending on the engine fitted) Vehicle diagnostic, testing and information system VAS 5051, Current flow diagrams, Electrical fault finding and Fitting locations
Different versions are fitted according to the vehicle equipment. Spare parts catalogue
Check the activation of the Climatronic control unit J255 Vehicle diagnostic, testing and information system VAS 5051 - 4 High-pressure sender G65
Operation, removing and fitting Chapter “Removing and fitting high-pressure senderG65”
The measurement value of the sender is viewed by the function „Read measurement block values“ of the Climatronic control unit J255 Chapter “Checking the pressure signal of the High pressure sender G65.” and Vehicle diagnostic, testing and information system VAS 5051 - 5 Service connection
High-pressure side
Used by specialised air conditioning workshops, to measure, empty and fill
Hood with seal, always screw into place
Depending on the version of the engine fitted, it may be necessary to remove certain components (for example the active carbon filter) to connect the service connection - 6 Service connection
Low-pressure section
Used by specialised air conditioning workshops, to measure, empty and fill
Hood with seal, always screw into place
Depending on the version of the engine fitted, it may be necessary to remove certain components (for example the active carbon filter) to connect the service connection - 7 Fresh air inlet cover
Check the correct positioning, ensure that water does not enter into the air conditioning inlet - 8 Fresh air inlet grill
Check the correct positioning, ensure that impurities (for example leaves) does not enter into the air conditioning inlet - 9 Fresh-air intake duct temperature sensor G89
Removing and fitting, check the resistance value Vehicle diagnostic, testing and information system VAS 5051
Only fitted in vehicles with automatic climate control until model year 2006 (gradually phased out in model year 2006) Note During the model year 2006 the thermosensor - fresh air intake channel G89 was gradually phased out; vehicles without this can only have control and indication panels,Climatronic control unit J255, with the part number from index „M“.If vehicles without thermosensor - fresh air intake channel G89 have a control and indicator panel, Climatronic control unit J255, with the part number up to index „L“, an entry is made in the fault memory.
Parts & tools for this job For 2004 SEAT Toledo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Toledo 2004 cabin filter