Removing, testing
- Make
- SEAT
- Model
- Toledo
- Year
- 5P, 2004–2009
- Section
- Heating and air conditioning › Removing, testing
Removing, testing
Remove the glove compartment and the central console Bodywork, interior fitting work Rep. Gr. 68.
Fold the floor covering back in the area of the condensation drainage hose until the tube can be seen Bodywork, interior fitting work Rep. Gr. 68.

Check the correct positioning of the condensation drainage tube (B) (eliminate any folding for example) and ensure that it is clean.
Cover the area under the passage (D) (for the drainage of the condensation water (C)) using absorbent paper (so that water does not go under the carpet).
Remove the condensation water drain (B).
Check if the condensation water drainage tube of the air conditioning (A) is clean, for example use a piece of wire.
Check the distance between the sound proofing cover fitted in the centre console and the condensation drainage valve (C) by the opening in the floor plate (D), there should be enough space for the water condensation to come out of the water drainage valve (C).

- Installing
Installation is carried out in the reverse order of removing, when doing this note the following.
Fit the condensation drainage (B) so that it is not bent or trapped.
Ensure during fitting of the floor mat that the condensation drainage tube is not crushed (B).