Installation is carried out in reverse order, noting the following:
Before fitting the compressor Air conditioning - with refrigerant R134a SEAT.
Note!
- Chapter “O-rings for refrigerant circuit”.
- Air conditioning - with refrigerant R134a SEAT.
- Chapter “Compressor on its holder: Removing and installing” and Chapter “Refrigerant pipes at compressor: detaching and attaching”.
- Parts catalogue.
Only ever start the engine after the complete assembly of the refrigerant circuit.
Following the fitting of a new compressor or refilling the refrigerant oil (after cleaning the refrigerant circuit) and before fitting the Poly-V belt, operate the compressor by hand for about 10 rotations before restarting the engine to avoid damage to the compressor.
Engine as soon as refrigerant circuit has been properly assembled.
Note!
- Chapter “Servicing the refrigerant circuit” and Spare parts catalogue.
- The compressor is always powered by a pulley (there is no magnetic coupling):
- . The requirement for the internal lubrication is that there is a residual amount of coolant left in the compressor.
- The engine can only be started when the coolant circuit is correctly fitted. If, e.g., the coolant pipes are not connected to the compressor, the compressor may heat up while the engine is running to such an extent (due to the interior heat) that it may be damaged beyond repair.
- Compressor regulation valve, air conditioning (01232) N280 is not activated when refrigerant circuit is empty and compressor runs at idle with engine.
- However, given that there is no refrigerant, the refrigeration oil necessary for compressor lubrication is not moved.
- .
- If the engine must be started with the refrigeration circuit empty:
- The refrigeration circuit must be assembled completely.
- There must be a minimum of 25 % of the required refrigeration oil for the lubrication circuit.
- The engine speed must not go above the 2500 rpm.
- The engine must only be used for the minimum amount of time.
When starting the engine for the first time following the filling of the refrigeration circuit, note the following:
Start the engine with the compressor deactivated. (For the Climatronic system, operation mode “Econ”, for the Climatic system, the button “AC” deselected) and wait until the stable idle engine speed has been reached.
Vehicles fitted with Climatronic:
Temperature preselection at lowest (for driver and passenger side) in Climatronic control unit (01320) J255.
Now activate the compressor (operation mode “Auto” and “Econ” deactivated) and let run, minimum, 5 min. with the engine at idle speed.
Vehicles fitted with Climatic
With the button “AC” pressed, the speed “1” of the Fresh air turbine (01273-4124) V2 is selected along with the lowest possible temperature.
Open all instrument panel vents.