Climate control not cooling
- Make
- Fiat
- Model
- 500 Factory Service Manual
- Year
- 2007–2024
- Section
- Climate control › Climate control not cooling
CLIMATE CONTROL NOT COOLING
The fan works properly and sends air to the passenger compartment according to the pre-set flows but the air remains at the outside temperature and is not cooled.
Engagement enablement of the coolant circuit is controlled by both the climate control node and the engine management node.
| Test results | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Connect the climate control system to the special repressurizing equipment and check the system pressures by carrying out the See Test 5040OB AIR CONDITIONING SYSTEM OPERATION CHECK (PRESSURE) Check that the engine cooling fan is working properly. | Move on to Step 4 | 1. Pressure not correct 2. Incorrect operation of engine cooling fan. | 1. Move on to Step 1 2. Carry out the | |
| 1 | CHECK FOR GAS LEAKS FROM CONDENSER | All OK | Problems encountered | Operation |
| With the engine started and the climate control system started (compressor button ON), check that the leak is by the system pipe housings or the seat for the drier filter or the pipe couplings at the condenser pack. | Move on to Step 2 | 1. Gas leak from condenser. 2. O-ring seals puckered. | 1. Replace the condenser Op. 5040A40 AIR CONDITIONING CONDENSER - R+R and refill correctly. 2. Replace the o-rings and refill correctly. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE Signal the point where the gas is escaping at the condenser | |
| 2 | CHECK FOR GAS LEAKS FROM EVAPORATOR | All OK | Problems encountered | Operation |
| With the engine started and the climate control system started (compressor button ON), using the leak detector, check that the leak is near the expansion valve or the bend in the pipes. | Move on to Step 3 | 1. Gas leak from evaporator. 2. O-ring seals puckered. | 1. Replace the evaporator Op. 5040C64 A/C EVAPORATOR - R+R and refill correctly 2. Replace the o-rings and refill correctly. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE Signal the point where the gas is escaping at the evaporator. | |
| 3 | CHECK FOR GAS LEAKS FROM COMPRESSOR | All OK | Problems encountered | Operation |
With the engine started and the climate control system at the maximum speed (compressor button ON), place the temperature adjustment button in the LO position, move the probe of the leak detector near the pipe outlet connector and check for any leaks. If there is a leak, repeat the test to make sure that there really is a leak. With the engine switched off, move the leak detector probe to the area of the compressor shaft and the compressor rear seal. If there is a leak, repeat the test to make sure that there really is a leak. | Move on to Step 4 | 1. O-ring seals puckered. 2. Leak from compressor shaft stem. 3. Leak from compressor rear seal. | 1. Replace the o-rings and refill correctly. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM - DEHYDRATE AND REPRESSURIZE 2. Replace the compressor. Op. 5040A20 AIR CONDITIONING COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY 3. Replace the compressor. Op. 5040A20 AIR CONDITIONING COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Connect the diagnostic equipment and check:
| Move on to Step 6 | 1. Error in the air mixture actuator. 2. Error in the treated air sensors 3. Error in the outside temperature sensor 4. Error at the frost sensor 5. Error at the passenger compartment temperature sensor. 6. Error at the linear sensor | 1. Move on to Step 5 2. Move on to Step 5 3. Move on to Step 5 4. Move on to Step 5 5. Move on to Step 5 6. Move on to Step 9 | |
| 5 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation and visually inspect for any looseness or damage at the electrical connection contacts:
| Move on to Step 10 | 1. Electrical connections loose or damaged. 2. Electrical connection broken or not insulated. | 1. Renew the electrical connections. 2. Restore the continuity/insulation of the electrical connection. | |
| 6 | PIPE AND FILTER CHECK | All OK | Problems encountered | Operation |
| Check that the air conditioning high and low pressure pipes are not blocked. | Move on to Step 7 | 1. Pipe from compressor to condenser obstructed. 2. Pipe from condenser to expansion valve obstructed. | 1. Replace the pipe from the compressor to the condenser. Op. 5040A50 PIPE FROM AIR CONDITIONING COMPRESSOR TO CONDENSER - R+R 2. Replace the pipe from the condenser to the expansion valve. | |
| 7 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Keeping the diagnostic equipment connected, check:
| Move on to Step 10 | 1. Errors in Engine Management Node. 2. The relay is activated and the coupling does not come on. 3. The relay comes on and the coupling is not activated. | 1. Continue as instructed by the diagnostic equipment 2. Move on to Step 8 3. Move on to Step 9 | |
| 8 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation of the electrical circuit for the compressor engagement relay. | Move on to Step 10 | 1. Electrical connections broken or not insulated. 2. Compressor engagement relay faulty. | 1. Restore the continuity/insulation of the electrical connections See E6021 COMPRESSOR ENGAGEMENT 2. Replace the compressor engagement relay. Op. | |
| 9 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation of the electrical power circuit for the compressor. | Move on to Step 10 | 1. Electrical connections broken or not insulated. 2. Electromagnet coupling faulty. | 1. Restore the continuity/insulation of the electrical connections See E6021 COMPRESSOR ENGAGEMENT 2. Replace the compressor complete with coupling. Op. 5040A20 AIR CONDITIONING COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY | |
| 10 | COMPRESSOR ENGAGEMENT CHECK | All OK | Problems encountered | Operation |
Check that the compressor comes on correctly by carrying out the See Test 5040BC CHECK ON CLIMATE CONTROL COMPRESSOR ACTIVATION/DEACTIVATION FROM LINEAR SENSOR | Move on to Step 11 | 1. Electrical connections broken 2. Linear sensor does not give OK | 1. Check and, if necessary, restore the continuity/insulation of the electrical connection. See E6021 COMPRESSOR ENGAGEMENT 2. Replace the linear sensor. Op. 5040B20 AIR CONDITIONING LINEAR PRESSURE TRANSDUCER - R.R. | |
| 11 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Check that the following errors do not persist:
| End of diagnosis | 1. Left air mixture actuator error. 2. Outside temperature sensor error. 3. Passenger compartment temperature sensor error. 4. Error at the demisting sensor. 5. Error at treated air sensors. | 1. Move on to Step 12 2. Replace the outside temperature sensor. Op. 5010D12 3. Replace the climate control system control unit. Op. 5040D14 4. Replace the frost sensor Op. 5040B64 SENSOR ON EVAPORATOR FOR A/C ECU - R + R 5. Replace the treated air sensors. | |
| 12 | CHECK FOR IMPEDIMENTS TO THE ROTATION OF THE MIXTURE ACTUATORS | All OK | Problems encountered | Operation |
| Remove the actuator and check using the control unit control that the actuator turns checking for mechanical impediments that prevent its rotation. | End of diagnosis | 1. The actuator does not turn. 2. Kinematic components or flaps broken/stuck | 1. Replace the mixture actuator. Op. 5040D56 COLLECTION OF ACTUATORS FOR AIR DISTRIBUTION AND MIXTURE FLAPS - WITH DASHBOARD TRIM REMOVED - R.R. 2. Replace the component that is faulty. | |
The fan works properly and sends air to the passenger compartment according to the pre-set flows but the air remains at the outside temperature and is not cooled.
Engagement enablement of the coolant circuit is controlled by both the climate control node and the engine management node.
| Test results | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Connect the climate control system to the special repressurizing equipment and check the system pressures by carrying out the See Test 5040OB AIR CONDITIONING SYSTEM OPERATION CHECK (PRESSURE) | Move on to Step 4 | Pressure not correct | Move on to Step 1. | |
| 1 | CHECK FOR GAS LEAKS FROM CONDENSER | All OK | Problems encountered | Operation |
| With the engine started and the climate control system started (compressor button ON), check that the leak is by the system pipe housings or the seat for the drier filter or the pipe couplings at the condenser pack. | Move on to Step 2 | 1. Gas leak from condenser. 2. O-ring seals puckered. | 1. Replace the condenser Op. 5040A40 AIR CONDITIONING CONDENSER - R+R and refill correctly. 2. Replace the o-rings and refill correctly. | |
| 2 | CHECK FOR GAS LEAKS FROM EVAPORATOR | All OK | Problems encountered | Operation |
| With the engine started and the climate control system on (compressor ON button), use the leak detector to check that the leak is from the expansion valve or by the bend in the pipes. | Move on to Step 3 | 1. Gas leak from evaporator. 2. O-ring seals puckered. | 1. Replace the evaporator Op. 5040C66 AIR CONDITIONING EVAPORATOR - R+R WITH AIR CONDITIONING CASING REMOVED and refill correctly 2. Replace the o-rings and refill correctly. | |
| 3 | CHECK FOR GAS LEAKS FROM COMPRESSOR | All OK | Problems encountered | Operation |
| With the engine started and the climate control system at the maximum speed (compressor button ON), place the temperature adjustment knob/button in the maximum cold position, move the probe of the leak detector near to the connector to be analysed and check for any leaks. If there is a leak, repeat the test to make sure that there really is a leak. | Move on to Step 4 | O-ring seals puckered. | Replace the o-rings and refill correctly. | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Connect the Examiner diagnostic equipment and check:
| Move on to Step 6 | 1. Error in the outside temperature sensor 2. Error at the frost sensor | 1. Move on to Step 5 2. Move on to Step 5 | |
| 5 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
Check the continuity/insulation of the electrical connection:
| Move on to Step 10 | Electrical connection broken or not insulated. | Restore the continuity/insulation of the electrical connection. | |
| 6 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Keeping the Examiner diagnostic equipment connected, check:
| Move on to Step 9 | 1. The relay comes on and the coupling is not activated. 2. The relay comes on and the coupling is not activated. | 1. Move on to Step 7 2. Move on to Step 8 | |
| 7 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
| Check the continuity/insulation of the electrical circuit for the compressor engagement relay. | Move on to Step 9 | 1. Electrical connections broken or not insulated. 2. Compressor engagement relay faulty | 1. Restore the continuity/insulation of the electrical connections. 2. Replace the compressor engagement relay. | |
| 8 | ELECTRICAL CIRCUIT CHECK | All OK | Problems encountered | Operation |
| Check the continuity/insulation of the electrical power circuit for the compressor | Move on to Step 9 | 1. Electrical connections broken or not insulated. 2. Electromagnetic coupling faulty | 1. Restore the continuity/insulation of the electrical connections. 2. Replace the compressor complete with coupling | |
| 9 | COMPRESSOR ENGAGEMENT CHECK | All OK | Problems encountered | Operation |
Check that the compressor comes on correctly by carrying out the See Test 5040BC CHECK ON CLIMATE CONTROL COMPRESSOR ACTIVATION/DEACTIVATION FROM LINEAR SENSOR | End of diagnosis | 1. Electrical connections broken 2. Linear sensor does not give go ahead | 1. Check and, if necessary, restore the continuity/insulation of the electrical connection. 2. Replace the linear sensor Op. 5040B20 AIR CONDITIONING LINEAR PRESSURE TRANSDUCER - R.R. | |
| 10 | CHECK ON CORRECT OPERATION USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Check that the following errors do not persist:
| End of diagnosis | 1. Outside temperature sensor error 2. Frost sensor error | 1. Replace the outside temperature sensor Op. 5010D12 2. Replace the frost sensor | |