  1. Unscrew the engine compartment protection screws.
  2. Remove the engine compartment protection.
Diagram showing the engine compartment protection with callout numbers 1 and 2
  1. Take out the engine coolant sleeve from the water pump and drain the liquid into a suitable container.
  2. Take out the water pump engine coolant pipe.
Diagram showing the alternator and water pump belt area with callout numbers 1 and 2
  1. Loosen the alternator fastening screws (1a) and remove the alternator / water pump belt (1b).
Diagram showing the engine water pump and belt assembly with callout numbers 1a and 1b
  1. Unscrew screws (1a) securing the engine water pump (1b) and remove it with its gasket.
Diagram showing the engine water pump with callout numbers 1a and 1b

Refitting

  • Assemble the engine water pump and fasten it with its screws.
  • Assemble the alternator / water pump belt.
  • Follow Op. 1092B54 Alternator / water pump BELT - Tension adjustment.
  • Insert the engine coolant pipe onto the water pump.
  • Insert the engine coolant sleeve onto the water pump.

(Cont.)