Workshop Manuals Factory service & repair Lancia
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Service news bulletins24 Special tools
Lancia Thesis Factory Service Manual (2002-2009)22 · Fault diagnosis
22 · Diagnostics

Rev counter not working

Make
Lancia
Model
Thesis Factory Service Manual
Year
2002–2009
Section
On-board instruments › Rev counter not working
Fault diagnosisRev counter not working

REV COUNTER NOT WORKING

With the engine running, the speedometer does not work or works irregularly;

the rpm signal is supplied by the "engine management node" and is made available to the "instrument panel node" via the "body computer node" gateway

STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
0PRELIMINARY CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the following with the engine running:

  • no fault message is displayed
Move on to StepFaults foundMove on to Step
1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Connect the Examiner diagnostic equipment to the diagnostic connector and check the following at the CAN:

  • no control unit not activated;
  • that there are no faulty control units;
  • no control unit with faulty CAN line;
Move on to Step1. Faults on CAN network1. Continue following the instructions for the diagnostic equipment
2. Errors on instrument panel nodeMove on to Step
2CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Keeping the Examiner diagnostic equipment connected to the diagnostic connector, check the following at the instrument panel node:in errors ambient

  • that there are no faults
Move on to StepPresence of errors or failed dialogue with the diagnostic equipmentContinue following the instructions for the diagnostic equipment
3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION

Keeping the Examiner connected, check the following on the instrument panel node:in active diagnosis ambient

  • the operation of the rpm indicator
Move on to StepRev counter not working

Replace instrument panel

See in Op. 5560B11 ANALOGUE CONTROL PANEL - R.R. or Replace

4CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present

Parts & tools for this job For 2002 Lancia Thesis

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.