Discovery II
GENERAL DATA
04-8
Fuel system - Td5
Fuel system - V8
Type
Direct injection from pressure regulated supply with cooled return flow
and in-line pressure regulator
Pressure regulator setting
4 bar (58 lbf.in
2
)
Pump
Electric two stage submersible
Pump output:
⇒
Low pressure
30 l/h (6.6 gal/h) (7.93 US gal/h) at 0.5 bar (7.25 lbf.in
2
)
⇒
High pressure
180 l/h (39.6 gal/h) (47.55 US gal/h) at 4 bar (58 lbf.in
2
)
Maximum consumption
30 l/h (6.6 gal/h) (7.93 US gal/h)
Injectors Make/type
Lucas EV1/Dual stage
Injector operating pressures:
Pre EU3 models
⇒
Initial opening pressure
270 bar (3915 lbf.in
2
)
⇒
Fully opened pressure
440 bar (6380 lbf.in
2
)
⇒
Maximum pressure
1560 bar (22620 lbf.in
2
)
EU3 models:
⇒
Initial opening pressure
270 bar (3915 lbf.in
2
)
⇒
Fully opened pressure
440 bar (6380 lbf.in
2
)
⇒
Maximum pressure
1750 bar (25375 lbf.in
2
)
Filter
In-line canister filter/water separator with water detection
Air cleaner
Mann and Hummell P0037
Type
Multiport injection from pressure regulated, returnless supply
Pump
Electric submersible
Regulated pump output pressure
3.5 bar (50.75 lbf.in
2
)
Fuel pump delivery
120 litres/hr (211 pints/hr) (234 US pints/hr)
Filter
In-line canister
Air filter
Mann and Hummell P0036