L322 Range Rover Service Procedures
AIR CONDITIONING
82-18
REPAIRS
Sensor - evaporator temperature - LHD
$% 82.20.95
Before disconnecting the battery, ensure all text and
cautions in the battery disconnection section are
observed.
GENERAL INFORMATION, Electrical
Remove
1. Set heater control to de-mist.
Failure to comply will result in damage to
footwell vent flap.
2. Disconnect battery earth lead.
3. Remove glove box.
4. Noting fitted position, disconnect 8 multiplugs
from fuse box.
5. Remove 4 Torx screws securing the fuse box,
position the fuse box aside.
6. Remove screw securing footwell heating duct
to fuse box mounting bracket. Remove duct.
7. Remove 4 Torx screws and spring clip from RH
heating duct elbow. Remove elbow.
CAUTION: Contain spring clip prior to
release.
8. Disconnect multiplug from evaporator sensor,
release harness and remove sensor.
Refit
1. Carefully fit sensor and secure grommet.
2. Connect multiplug and secure harness.
3. Position and secure heating duct elbow.
4. Position and secure footwell heating duct.
5. Position fuse box and secure with screws.
6. Connect multiplugs to fuse box.
7. Fit glove box.
8. Connect battery earth lead.
Sensor - evaporator temperature - RHD
$% 82.20.95
Before disconnecting the battery, ensure all text and
cautions in the battery disconnection section are
observed.
GENERAL INFORMATION, Electrical
Remove
1. Set heater control to de-mist.
CAUTION: Failure to comply will result in
damage to footwell vent flap.
2. Disconnect battery earth lead.
3. Remove closing panel.
Closing panel - passenger side.
4. Remove shroud.
5. Remove screw securing footwell heating duct
to carrier. Remove duct.
6. Remove 4 Torx screws and spring clip from RH
heating duct elbow. Remove elbow.
CAUTION: Contain spring clip prior to
release.
7. Disconnect multiplug from evaporator sensor,
release harness and remove sensor.
Refit
1. Carefully fit sensor and secure grommet.
2. Connect multiplug to sensor and secure
harness.
3. Position and secure heating duct elbow.
4. Position and secure footwell heating duct.
5. Fit shroud.
6. Fit closing panel.