Workshop Manuals Factory service & repair Land Rover
01 Range Rover Classic - 199502 01 - INTRODUCTION03 04 - GENERAL SPECIFICATION DATA04 05 - ENGINE TUNING DATA05 06 07 - GENERAL FITTING REMINDERS07 09 - LUBRICANTS, FLUIDS AND CAPACITIES08 10 - MAINTENANCE09 12 - ENGINE - Tdi10 11 12 13 12 - ENGINE - V8i14 17 - EMISSION CONTROL15 19 - FUEL SYSTEM - Tdi16 19 - FUEL SYSTEM - MFI17 19 - FUEL SYSTEM - CRUISE CONTROL - V8i18 26 - COOLING SYSTEM - Tdi19 26 - COOLING SYSTEM - V8i20 30 - MANIFOLD AND EXHAUST SYSTEM21 33 - CLUTCH22 37 - MANUAL GEARBOX - R38023 41 - TRANSFER GEARBOX - BORG WARNER24 25 44 - AUTOMATIC GEARBOX - ZF26 27 28 47 - PROPELLER SHAFTS29 51 - REAR AXLE AND FINAL DRIVE30 31 54 - FRONT AXLE AND FINAL DRIVE32 33 34 57 - STEERING35 36 37 60 - FRONT SUSPENSION38 64 - REAR SUSPENSION39 68 - AIR SUSPENSION40 70 - BRAKES - NON ABS41 70 - BRAKES - ABS42 70 - BRAKES - ELECTRONIC TRACTION CONTROL43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 74 - WHEELS AND TYRES59 75 - SUPPLEMENTARY RESTRAINT SYSTEM60 76 - CHASSIS AND BODY61 62 63 64 80 - HEATING AND VENTILATION65 82 - AIR CONDITIONING66 84 - WIPERS AND WASHERS67 86 - ELECTRICAL
Land Rover Range Rover Classic65 · 82 - AIR CONDITIONING
65 · Heating & A/C

SERVICING PRECAUTIONS

Make
Land Rover
Model
Range Rover Classic
Section
ADJUSTMENT › SERVICING PRECAUTIONS
82 - AIR CONDITIONINGSERVICING PRECAUTIONS
background image

82

AIR CONDITIONING

2

ADJUSTMENT

SERVICING PRECAUTIONS

Care must be taken when handling refrigeration
system components. Units must not be lifted by their
hoses, pipes or capillary lines. Hoses and lines must
not be subjected to any twist or stress. Ensure that
hoses are positioned in their correct run before fully
tightening the couplings, and ensure that all clips and
supports are used. Torque wrenches of the correct
type must be used when tightening refrigerant
connections to the stated value. An additional spanner
must be used to hold the union to prevent twisting of
the pipe.
Before connecting any hose or pipe ensure that
refrigerant oil is applied to the seat of the new ’0’ ring
but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs on components must be left in
place until immediately prior to connection.
The receiver/drier contains desiccant which absorbs
moisture. It must be positively sealed at all times.

CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating

and recharging the system.

Use alcohol and a clean cloth to clean dirty
connections.
Ensure that all new parts fitted are marked for use
with R134a.

Refrigerant oil

Use the approved refrigerant lubricating oil:
Nippon Denso ND-OIL 8
Unipart R134a ND-OIL8

CAUTION: Do not use any other type of
refrigerant oil.

Refrigerant oil easily absorbs water and must not be
stored for long periods. Do not pour unused oil back
into the container.
When renewing system components, add the
following quantities of refrigerant oil:

Condenser

40 ml

.........................................................

Evaporator

80 ml

.........................................................

Pipe or hose

20 ml

.......................................................

Receiver/drier

20 ml

.....................................................

Total quantity of refrigerant oil in system = 180 ml =
6.3 Fl oz

A new compressor is sealed and pressurised with
Nitrogen gas, slowly release the sealing cap, gas
pressure should be heard to release as the seal is
broken.

NOTE: A new compressor should always
have its sealing caps in place and must
not be removed until immediately prior to

fitting.

Fitting a new compressor
A new compressor is supplied with an oil fill (X) of:
180 ml
A calculated quantity of oil must be drained from a
new compressor before fitting.
To calculate the quantity of oil to be drained:

1. Remove sealing plugs from the OLD compressor
2. Invert compressor and gravity drain oil into

measuring cylinder. Rotating the compressor
clutch plate will assist complete draining.

3. Note the quantity of oil drained (Y).
4. Calculate the quantity (Q) of oil to be drained

from the NEW compressor using the following
formula:

X - (Y + 20 ml) = Q

Rapid refrigerant discharge
When the air conditioning system is involved in
accident damage and the circuit is punctured, the
refrigerant is discharged rapidly. The rapid discharge
of refrigerant will also result in the loss of most of the
oil from the system. The compressor must be
removed and all the remaining oil in the compressor
drained and refilled as follows:

1. Gravity drain all the oil, assist by rotating the

clutch plate (not the pulley).

2. Refill the compressor with the following amount

of new refrigerant oil:

130 ml

3. Plug the inlet and outlet ports.

Parts & tools for this job For Land Rover Range Rover

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.