Atomization inspection
- Make
- Mazda
- Model
- MX-5 (NC) Factory Workshop Manual
- Year
- 2006–2008
- Section
- Fuel System › Atomization inspection
EngineAtomization inspection · page 1 of 2
Courtesy of MAZDA MOTORS CORP.
- Turn the ignition switch to the ON position to operate the fuel pump.
- Measure the injection volume of each fuel injector.
- If not within the specification, replace the fuel injector. (See FUEL INJECTOR REMOVAL/INSTALLATION [LF] .)
Fuel injection volume
204-216 ml {204-216 cc, 12.5-13.1 cu in}/min
- Turn the ignition switch to off to stop the fuel pump.
- Install the fuel injector. (See FUEL INJECTOR REMOVAL/INSTALLATION [LF] .)
- Complete the "AFTER SERVICE PRECAUTION". (See AFTER SERVICE PRECAUTION [LF] .)
ATOMIZATION INSPECTION
- Inspect the atomization status.
- If not normal, replace the fuel injector. (See FUEL INJECTOR REMOVAL/INSTALLATION