01 Engine - Td402 Engine - K Series 1.803 Engine - K Series KV604 Emission control - Td405 Emission control - K Series 1.806 Emission control - K Series KV607 Engine management system - EDC08 Engine management system - MEMS09 Engine management system - siemens (all except NAS)10 Engine management system11 Fuel delivery system - Td412 Fuel delivery system - K Series 1.813 Fuel delivery system - K Series KV614 Cooling system - Td415 Cooling system - K Series 1.816 Cooling system - K Series KV617 Manifold and exhaust system - Td418 Manifold and exhaust system - K Series 1.819 Manifold and exhaust system - K Series KV620 Clutch21 Manual gearbox - Getrag22 Intermediate reduction drive23 Automatic gearbox - Jatco24 Driveshafts25 Rear axle and final drive26 Steering27 Front suspension28 Rear suspension29 Brakes30 Restraint systems31 Heating and ventilation32 Air conditioning33 Wipers and washers34 Control units35 Communication data buses36 Security37 Windows38 Navigation system39 Instruments
Land Rover Freelander System Description and Operation (UK)31 · Heating and ventilation
31 · Heating & A/C

Cool Down Times (Heating and ventilation)

Make
Land Rover
Model
Freelander System Description and Operation (UK)
Section
Description and operation › Cool Down Times
Heating and ventilationCool Down Times

Coolant Temperature Control When the ECU first enters the active mode, it initiates a start to full load combustion. Full load combustion continues until the heat exchanger casing temperature reaches 60 °C (140 °F), at this point the ECU decreases the speed of the FBH fuel pump and the combustion air fan to half speed, to produce part load combustion. The ECU maintains part load combustion while the heat exchanger casing temperature remains between 54 and 65 °C (129 °C and 149 °F). If the heat exchanger casing temperature decreases to 54 °C (129 °F), the ECU switches the system to full load combustion again. If the heat exchanger casing temperature increases to 65 °C (149 °F), the ECU enters a control idle phase of operation.

On entering the control idle phase, the ECU immediately switches the FBH fuel pump off, to stop combustion, and starts a timer for the combustion air fan. After a 2 minute cool down period, the ECU switches the combustion air fan off and then remains in the control idle phase while the heat exchanger casing temperature remains above 59 °C (138 °F). If the heat exchanger casing temperature decreases to 59 °C (138 °F), within 15 minutes of the ECU entering the control idle phase, the ECU initiates a start to part load combustion. If more than 15 minutes elapse before the heat exchanger casing temperature decreases to 59 °C (138 °F), the ECU initiates a start to full load combustion.

In order to limit the build up of carbon deposits on the glow plug/flame sensor, the ECU also enters the control idle phase if the continuous part and/or full load combustion time exceeds 72 minutes. After the cool down period, if the heat exchanger casing is still in the temperature range that requires additional heat, the ECU initiates an immediate restart to part or full load combustion as appropriate.

Shutdown The FBH system is de-activated when the alternator power supply to the FBH unit is disconnected, either by the engine stopping or, if the ambient temperature increases to 5 °C (41 °F) or above, by the contacts in the air temperature sensor opening. If the system is active when the alternator power supply is disconnected, the ECU deenergises the FBH fuel pump to stop combustion, but continues operation of the combustion air fan and the circulation pump to cool down the FBH unit. The cool down time depends on the combustion load at the time the alternator power input is disconnected.

Cool Down Times

Combustion LoadCool Down Time, Seconds
Part100
Full175

Diagnostics The ECU in the FBH unit monitors the system for faults. Any faults detected are stored in volatile memory in the ECU, which can be interrogated by Testbook/T4. A maximum of three faults and associated freeze frame data can be stored at any one time. If a further fault is detected, the oldest fault is overwritten by the new fault.

The ECU also incorporates an error lockout mode of operation that inhibits system operation to prevent serious faults from causing further damage to the system. In the error lockout mode, the ECU immediately stops the FBH fuel pump, and stops the combustion air fan and circulation pump after a cool down time of approximately 2 minutes. Error lockout occurs for start sequence failures and/or combustion flameouts, heat exchanger casing overheat and out of limit input voltage. The error lockout mode can be cleared using Testbook/T4, or by disconnecting the battery power supply for a minimum of 10 seconds.

Start Failure/Flameout: If a start sequence fails to establish combustion, or a flameout occurs after combustion is established, the ECU immediately initiates another start sequence. The start failure or flameout is also recorded by an event timer in the ECU. The event timer is increased by one after each start failure or flameout, and decreased by one if a subsequent start is successful. If the event timer increases to three (over any number of drive cycles), the ECU enters the error lockout mode.

Heat Exchanger Casing Overheat: To protect the system from excessive temperatures, the ECU enters the error lockout mode if the heat exchanger casing temperature exceeds 105 °C (221 °F).

Out of Limit Voltage: The ECU enters the error lockout mode if the battery or alternator power input is less than 10.5 ± 0.3V for more than 20 seconds, or more than 15.5 ± 0.5V for more than 6 seconds.