L322 Range Rover Service Procedures
ENGINE MANAGEMENT SYSTEM - V8
REPAIRS
18-2-7
Refit
1. Ensure mating faces of ECT sensor and
coolant pump are clean.
2. Fit new seal and tighten ECT sensor to 15 Nm
(11 lbf.ft).
3. Connect multiplug to ECT sensor.
4. Remove container.
5. Dispose of coolant and clean container.
6. Connect battery earth lead.
7. Check and top up cooling system.
8. If a replacement sensor has been fitted re-set
adaptions using TestBook/T4.
Sensor - crankshaft position (CKP)
$% 18.30.12
Before disconnecting the battery, ensure all text and
cautions in the battery disconnection section are
observed.
GENERAL INFORMATION, Electrical
Remove
1. Position vehicle on lift.
2. Disconnect battery earth lead.
3. Raise vehicle and disconnect multiplug from
CKP sensor.
4. Clean area surrounding CKP sensor.
5. Remove Allen screw and remove CKP sensor.
Refit
1. Clean casing mating face.