Doors open check warning light on
- Make
- Alfa Romeo
- Model
- GT Factory Service Manual
- Year
- 2003–2010
- Section
- Instrument panel › Doors open check warning light on
DOORS OPEN CHECK WARNING LIGHT ON
The door open symbol in the Instrument Panel Node matrix remains on.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check that the two doors and the boot are properly shut | Continue to Step 1 | Doors not properly closed | Make sure they are properly closed. If the fault persists. Continue to Step 1 | |
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. | Continue to Step 5 | Impossible to connect with the Instrument Panel control unit | Continue to Step 2 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| 2 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Instrument Panel Node electrical power supply is correct | Continue to Step 3 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 3 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. | Continue to Step 4 | Electrical connections not working | Restore damaged electrical connections. | |
| 4 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Instrument Panel Node | Continue to Step 5 | Impossible to connect with the Instrument Panel | Replace the instrument panel Op. | |
| 5 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check, in the Body Computer Node ambient, that there are no errors and the door status parameter varies | Continue to Step 1 | Impossible to connect with the Body Computer control unit | Continue to Step 6 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| The parameter values do not change | Continue to Step 9 | |||
| 6 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Body Computer Node electrical power supply is correct | Continue to Step 7 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 7 | CHECK ON CONNECTIONS | All OK | Problems met | Operation |
| Check the continuity of the wiring between the door lock geared motors and the Body Computer Node and between the boot opening switch and the Body Computer Node | Continue to Step 8 | Door electrical connections not working | Restore damaged electrical connections See | |
| Boot electrical connections not working | Restore damaged electrical connections See | |||
| 8 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Body Computer Node | Continue to Step 5 | Impossible to connect with the Body Computer control unit | Replace the Body Computer Node Op. | |
| 9 | CHECK ON CONNECTIONS | All OK | Problems met | Operation |
| Check the continuity of the wiring between the door lock geared motors and the Body Computer Node and between the boot opening switch and the Body Computer Node | Continue to Step 10 | Door electrical connections not working | Restore damaged electrical connections See | |
| Boot electrical connections not working | Restore damaged electrical connections. See | |||
| 10 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Continue to Step 1 | |
The lights check symbol in the Instrument Panel Node matrix appears.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Turn the key to the PARK position, move the steering column switch unit lever and check that the parking lights come on correctly. Press the hazard warning lights switch and check that they are correctly activated. Then turn the ignition key to the ON position and check that the side/no. plate lights are working. Activate the rear fog lamp using the control panel and check that it is working properly. Operate the direction indicators using the stalk lever and check that they are working properly Press the brake pedal and check that the brake lights come on | Continue to Step 1 | Parking lights not working | Continue as instructed See table | |
| Side/no. plate lights not working | Continue as instructed See table | |||
| Hazard warning lights not working | Continue as instructed See table See table I39 TURN SIGNALS DO NOT WORK WHEN HAZARD KEY IS PRESSED | |||
| Direction indicators not working | Continue as instructed See table See table I10 DIRECTION INDICATORS / HAZARD WARNING LIGHTS / NOT WORKING | |||
| Rear fog lamps not working | Continue as instructed See table | |||
| Brake lights not working | Continue as instructed See table See table I14 BRAKE LIGHTS AND THIRD BRAKE LIGHT NOT WORKING | |||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner check, in the Instrument Panel Node ambient, that there are no errors and the following parameters are present. | Continue to Step 5 | Impossible to connect with the Instrument Panel control unit | Continue to Step 2 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| 2 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Instrument Panel Node electrical power supply is correct. | Continue to Step 3 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 3 | CHECK ELECTRICAL CONNECTIONS | All OK | Problems met | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel, in particular that each individual pin is correctly connected. | Continue to Step 4 | Electrical connections not working | Restore damaged electrical connections. | |
| 4 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Instrument Panel Node | Continue to Step 5 | Impossible to connect with the Instrument Panel | Replace the instrument panel Op. | |
| 5 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check, in the Body Computer Node ambient, that there are no errors and the specific parameter varies | Continue to Step 1 | Impossible to connect with the Body Computer control unit | Continue to Step 6 | |
| There are errors | Continue in accordance with the instructions for the diagnostic equipment | |||
| The parameter values do not change | Continue to Step 9 | |||
| 6 | ELECTRIC POWER SUPPLY CHECK | All OK | Problems met | Operation |
| Check that the Body Computer Node electrical power supply is correct | Continue to Step 7 | Positive and/or earth electrical power supply faulty | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |
| 7 | CHECK ON CONNECTIONS | All OK | Problems met | Operation |
| Check the continuity of the wiring between the various bulbs and the Body Computer Node | Continue to Step 8 | Electrical connections not working | Restore damaged electrical connections. | |
| 8 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Using the Examiner, check the possibility of connecting with the Body Computer Node | Continue to Step 5 | Impossible to connect with the Body Computer control unit | Replace the Body Computer Node Op. | |
| 9 | CHECK ON CONNECTIONS | All OK | Problems met | Operation |
| Check the continuity of the wiring between the various bulbs and the Body Computer Node | Continue to Step 10 | Electrical wiring not working | Renew the damaged wiring | |
| 10 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Continue to Step 1 | |
Parts & tools for this job For 2003 Alfa Romeo GT
- TOOLTrim removal tool kitSearch: trim removal tool kit
- PARTTouch-up paintSearch: Alfa Romeo touch up paint
- PARTPanel clip assortmentSearch: Alfa Romeo panel clips assortment
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.