Before disconnecting the battery, ensure all text and
cautions in the battery disconnection section are
observed.
GENERAL INFORMATION, Electrical
Remove
1. Disconnect battery earth lead.
2. Remove fan cowl.
3. Loosen 2 ancillary drive belt tensioner bolts.
4. Using a 17 mm (11/16 in) spanner, rotate belt
tensioner fully clockwise to release tension on
ancillary drive belt.
5. Hold tensioner in retracted position and tighten
tensioner clamping bolt.
6. Release ancillary drive belt from tensioner
pulley.
7. Remove nut securing tensioner to tensioner
adjusting bracket.
8. Remove 2 bolts securing ancillary drive belt
tensioner to lower timing gear cover.