DIAGNOSTICS 

The diagnostic socket is located in the lower instrument panel closing panel, on the driver's side, below the steering 
column. 
 
The diagnostic socket allows the exchange of information between the various modules on the bus systems and T4 or a 
diagnostic tool using ISO14229 protocol. The information is communicated to the socket via the high speed CAN bus from 
the TCM. This allows the retrieval of diagnostic information and programming of certain functions using T4 or a suitable 
diagnostic tool. 
 
The TCM uses a P code strategy which stores industry standard Diagnostic Trouble Codes (DTC) relating to faults. 
 

16 

Ground 2 

P Code 

Component/Signal 

Fault Description 

P012100 

Kickdown 

Signal not plausible 

P021900 

Stall speed/engine overspeed 

Signal not plausible 

P050000 

Wheel speeds plausible signal 

General fault type 

P050100 

Wheels speeds plausible signal 

Signal not plausible 

P056100 

Power supply (battery) 

General fault type 

P056200 

Power supply (battery) 

Signal voltage too low 

P056300 

Power supply (battery) 

Signal voltage too high 

P060100 

EPROM/FLASH Checksum 

Signal not plausible 

P060300 

Battery buffered RAM 

Signal not plausible 

P060500 

EPROM/FLASH Checksum after 

software verification 

Signal not plausible 

P061300 

Watchdog locking mechanism 

General fault type Signal not plausible Short circuit to power supply 

Short circuit to ground Circuit break Short circuit to ground or power 

break Signal voltage too high Signal voltage too low Function specific, 

see monitoring function 

P061300 

Micro controller components 

General fault type No change in signal Function specific, see monitoring 

function 

P062F00 

EEPROM communication 

General fault type 

P064100 

Sensor supply voltage 

Signal voltage too high or too low 

P065700 

Power supply pressure regulators 

and solenoids 

Signal not plausible Circuit break 

P065800 

Power supply pressure regulators 

and solenoids 

Short circuit to ground 

P065900 

Power supply pressure regulators 

and solenoids 

Short circuit to power supply 

P066800 

Micro processor chip temperature 

sensor 

Signal voltage too low 

P066900 

Micro processor chip temperature 

sensor 

Signal voltage too high 

P070000 

Combination of impossible 

substitute functions 

General fault type Signal not plausible Signal voltage too high 

P070500 

Selector position switch 

Signal not plausible 

P071000 

Transmission oil temperature 

Circuit break 

P071100 

Transmission oil temperature 

General fault type Signal voltage too high 

P071200 

Transmission oil temperature 

Short circuit to ground 

P071300 

Transmission oil temperature 

Short circuit to power supply 

P071600  Transmission turbine speed sensor 

Short circuit to ground or power break Signal voltage too high Signal 

voltage too low 