Workshop Manuals Factory service & repair Fiat
01 00 Introduction and technical data02 10 Engine03 33 Braking system04 41 Steering05 50 Subsidiary components06 55 Electrical equipment07 70 Bodywork
Fiat Scudo Factory Service Manual (1996-2006)01 · 00 Introduction and technical data
01 · General

Micro-switch check

Make
Fiat
Model
Scudo Factory Service Manual
Year
1996–2006
Section
Engine › Micro-switch check
00 Introduction and technical dataMicro-switch check
Type of check Adjustment lever position Rotation speed rpm Advance check mm Transfer pressure bar Capacity per element mm³/cycle Max. disc. btwn ind. flow rates mm³/cycle Supercharg. pressure bar
Delay device check (LFB) Shuttered 1250 -1,0±0,3 – Q max -(7±3) (▲▲) – –
Device check (ALFB) (■) Shuttered 1250 0÷08 – 2÷8 – –
Fast idle device (LFG) (▲) Min 475 – – 5,5÷13,5 – –
3rd stop setting (■■) Shuttered 1000 – – 12÷17 – –

Connection fixed advance (after engine TDC)=

Fitting procedure: with cylinder n° 1 at TDC set the pump so that the pump stroke is equal to 0.90 mm.

Electrical stop control: minimum operating voltage 8 V. Rated voltage 11-13V.
Maximum free running engine speed: 5300±50 rpm.
Engine idle speed: 800+0-50 rpm.

  • (●) Fuel return from the pump to the tank.
  • (●●) To be carried out with the electrical stop control switched off.
  • (▲) LFG lever in end of travel position on right stop.
  • (▲▲) Q max= intake capacity.
  • (■) Supply the solenoid valve at 12V.
  • (■■) Insert a 12 mm sensor between the accelerator lever and the 3rd stop screw.

Micro-switch check

  1. Contact open = lever travel 11,6 mm
  2. Contact closed = lever trave; 12,4 mm

Parts & tools for this job For 1996 Fiat Scudo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.