(Op. 5040B30continued)
- Check that the expansion valve is not damaged or clogged.
- Refit the expansion valve with the plate and tighten the fastening screws to correct torque
| Attachment | Component | Ø | Value (daNm) |
| - | Screw | EXPANSION VALVE SYSTEM (A.C) | M6 | 0.9 |
- Refit the heater pipes support and fasten with the screws.
- Join the pipe of the dehydration filter/expansion valve to the expansion valve and tighten the nut to correct torque
| Attachment | Component | Ø | Value (daNm) |
| - | Nut | PIPE OF DEHYDRATION FILTER/ EXPANSION VALVE | M6 | 0.9 |
- Join the pipe of the expansion valve/compressor to the expansion valve and tighten the nut to correct torque
| Attachment | Component | Ø | Value (daNm) |
| - | Nut | PIPE OF EXPANSION VALVE/ COMPRESSOR | M6 | 0.9 |
- Complete with Op. 5040A10 Air conditioner cooling CIRCUIT - Dehydration and Recharging.