seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Capacity > < Instrument panel diffusers and air conduits
Safety precautions when handling refrigerants
Safety precautions when handling refrigerants
  Note
t  Safety precautions for repair work to vehicles with air conditioning system and for handling refrigerant can be found in ELSA under → Air conditioning system with refrigerant R134a ; Rep. gr.00.
t  Notes on testers and tools for repair work to vehicles with air conditioning can be found in ELSA under → Air conditioning system with refrigerant R134a; Rep. gr.00.
t  If the evaporator gives off unpleasant odours, clean it using the ultrasonic air conditioner cleaning unit -VAS 6189A- or the suction feed spray-gun -V.A.G 1538- and the appropriate probe for evaporator cleaning. Comprehensive information on how to proceed is supplied with the appliances.
  Caution
Do not kink or severely bend refrigerant lines.
There is a film in the refrigerant lines which can be destroyed.
Refrigerant lines must not be bent to a radius less than r = 100 mm.
Further information can be found under:
t  → Current flow diagrams, Electrical fault finding and Fitting locations
   

Capacity > < Instrument panel diffusers and air conduits