Workshop Manuals Factory service & repair Alfa Romeo
01 General data and specifications02 Maintenance03 Diagnosis – checks04 Engine (1.6 and 2.0 Twin Spark)05 Clutch06 Gearbox (manual and Selespeed)07 Front axle08 Brakes, ABS and traction control09 Steering10 Suspension and wheels11 Heating, air conditioning and washers12 Electrical equipment13 Body14 Body panels and reinforcement15 Wiring diagrams16 Connectors and pin-outs17 Wiring harnesses18 Fault diagnosis19 Special tools
Alfa Romeo 147 Factory Service Manual (2000-2002)12 · Electrical equipment
12 · Electrical

Deactivation

Make
Alfa Romeo
Model
147 Factory Service Manual
Year
2000–2002
Section
Special accessories › Deactivation
Electrical equipmentDeactivation

DEACTIVATION

Deactivation may take place either in the surveillance state, or in the alarm state.

It is carried out by pressing the button on the transmitter, which instructs the BC to deactivate the alarm system in accordance with the following procedure: deactivation is indicated by two flashes of the blinkers at 1Hz ± 10%, d.c. 50% and two

beeps (the indication is enabled/disabled depending on the operating mode).

This indication is activated within 100 ms from receipt of the deactivation command:

  • the siren is deactivated.
  • the external modules are deactivated.
  • the BC interrupts perimter protection and all counter-measures in progress, if there are any.

The command is also accepted in the presence of the +15 signal.

After carrying out deactivation and at the first Key-On, the control unit indicates discharged transmitter batteries, alarms from volumetric, anti-tilt, perimeter sensors,+15 and +30.

The indication takes place by the flashing of the dissuasion light for 120 ± 10% s.

The meanings of the flashing are as follows:

Light on fixed: transmitterbatteries discharged (disguises all the indications)
1 flashone or more doors
2 flashesboot
3 flashesbonnet
4 flashesultrasound module
5 flashesanti-tilt module
6 flashes+15
7 flashes+30/earth
8 flashesserial line (no signal/incorrect signal from siren for more than 3 times)
9 flashesat least three causes of alarm

The flashes last 0.5 s ON, 0.5 s OFF and the indications are repeated after a pause of 1.5 s. If there are two different causes of alarm, these are displayed in cycles.