01 cover02 A (intro)03 B (CA18DET/ECCS)04 C (driveline)05 D (body & frame)06 E (interior electric)07 F (misc. codes)08 manual notes09 Front cover10 CONTENTS11 GI General information12 MA maintenance13 EM engine mechanical14 LC lubrication & cooling15 EF &EC engine fuel & emission control system16 FE engine control fuel & exhaust systems17 CL clutch18 MT manual transmission19 AT automatic transmission20 PD prop shaft & diff carrier21 FA front axle & suspension22 RA rear axle & suspension23 BR brake system24 ST steering25 BF body26 HA heater & aircon27 EL electrical system
Nissan and Datsun Nissan 180SX S13 1989 Workshop Manual26 · HA heater & aircon
26 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

Make
Nissan and Datsun
Model
180SX Nissan 180SX S13 1989 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual
HA heater & airconDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Point-1 |

To high-pressure To low-pressure . service valve service valve 3 ¢ Discharging

Low (ean

High Slowly open the valves to discharge only refrigerant. If they are opened quickly, compressor oil will also be discharged.

| 4 Stowly open

« SHA240B

| Point-2 |

To low-pressure To high-pressure service valve service valve Evacuating the System

1. Start pump, then open both vaives and run pump for over 5 minutes.

2. When low gauge has reached approx. 98.6 to 101.3 kPa (986 to 1,013 mbar, 740 to 760 mmHg, 29.13 to 29.92 inHg), completely close both valves of gauge and stop vacuum pump.

a. The low-pressure gauge reads lower by 3.3 kPa (33 mbar, Vacuum pump SHA241B 25 mmHg, 0.98 inHg) per 300 m (1,000 ft) elevation. Perform evacuation according to the following table. Elevation Vacuum of system*

b. The rate ascension of the low-pressure gauge should be m (ft) kPa (mbar, mmHg, inHg) less than 3.3 kPa (33 mbar, 25 mmHg, 0.98 inHg) in 5 0 (0) 101.3 (1,013, 760, 29.92) minutes. 300 (1,000)

98.0 (980, 735, 28.94) 600 (2,000)

94.6 (946, 710, 27.95) 900 (3,000)

91.3 (913, 685, 26,97) *: Values show reading of the low-pressure gauge.

Checking Airtightness

1. Close both low and high-pressure valves and leave them unattended for approx. 5 to 10 minutes.

2. Make sure the pointer of the low-pressure gauge does not deflect toward the “0” direction.

3. If the pointer deflects, gas leakage is present. Repair as

outlined under [Point-4].

Repair If a malfunction is noticed under above, locate and repair the leaking point using the following table as a guide.

Leak at/around pipe connectionLeak at/around gauge manifold
®Oring fouled, damaged or@Malfunctioning charging hose
deformed@Gauge improperly installed
®@Ojl not applied to pipe connec-@Maifunctioning valve
tions during installation@Malfunctioning packing, etc.
®@Pipe connections not properly
tightened (too tight or too loase)