Workshop Manuals Factory service & repair Nissan and Datsun
01 cover02 A (intro)03 B (CA18DET/ECCS)04 C (driveline)05 D (body & frame)06 E (interior electric)07 F (misc. codes)08 manual notes09 Front cover10 CONTENTS11 GI General information12 MA maintenance13 EM engine mechanical14 LC lubrication & cooling15 EF &EC engine fuel & emission control system16 FE engine control fuel & exhaust systems17 CL clutch18 MT manual transmission19 AT automatic transmission20 PD prop shaft & diff carrier21 FA front axle & suspension22 RA rear axle & suspension23 BR brake system24 ST steering25 BF body26 HA heater & aircon27 EL electrical system
Nissan and Datsun Nissan 180SX S13 1989 Workshop Manual26 · HA heater & aircon
26 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

Make
Nissan and Datsun
Model
180SX Nissan 180SX S13 1989 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual
HA heater & airconDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

To low-pressure To high-pressure Point-5 service valve service valve Evacuating the System

1. Close manifold gauge valve securely and disconnect charg- ing hose from refrigerant can. Gonnect center charging hose to vacuum pump.

2.

3. Start pump, then open both valves and run pump for over 20 minutes.

SHA2418 Point-6 Charging

1. Close manifold gauge valves securely and disconnect charging hose from vacuum pump. . Purge air from center charging hose. 1) Connect center charging hose to refrigerant can through charge valve. 2) Break seal of refrigerant can and purge air. SHA2428

3. Charge refrigerant into system. To low-pressure To high-pressure service valve service valve

WARNING: Ensure that engine is off. 1) Open high-pressure valve of manifold gauge and charge refrigerant into system.

RHA278

CAUTION: Tao high-pressure if charging liquefied refrigerant into the system with the can To low-pressure service valve service valve

turned upside down to reduce charging time, charge it only

through high-pressure (discharge) service valve. After charg- ing, the compressor should always be turned several times manually. 2) When low-pressure gauge reading is 98 kPa (0.98 bar, 1.0

kg/cm’, 14 psi), completely close high-pressure valve of

manifold gauge and stop charging. SHA244B

HA-23

Parts & tools for this job For Nissan 180SX

As an Amazon Associate we earn from qualifying purchases.