01 cover02 A (intro)03 B (CA18DET/ECCS)04 C (driveline)05 D (body & frame)06 E (interior electric)07 F (misc. codes)08 manual notes09 Front cover10 CONTENTS11 GI General information12 MA maintenance13 EM engine mechanical14 LC lubrication & cooling15 EF &EC engine fuel & emission control system16 FE engine control fuel & exhaust systems17 CL clutch18 MT manual transmission19 AT automatic transmission20 PD prop shaft & diff carrier21 FA front axle & suspension22 RA rear axle & suspension23 BR brake system24 ST steering25 BF body26 HA heater & aircon27 EL electrical system
Nissan and Datsun Nissan 180SX S13 1989 Workshop Manual26 · HA heater & aircon
26 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

Make
Nissan and Datsun
Model
180SX Nissan 180SX S13 1989 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual
HA heater & airconDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Checking Refrigerant Level

CONDITION @

Door window:

Open

A/C switch:

ON @

TEMP. lever position:

Max. COLD

®

FAN lever position:

4 @

Check sight glass after a japse of about five

minutes.

Amount of refrigerant

Almost no refrigerant

insufficient Suitable

Too much refrigerant

Check item Temperature of high- Almost no difference be- High-pressure side is warm High-pressure side is hot High-pressure side is ab- pressure and low- tween high-pressure and and low-pressure side is and low-pressure side is normally hot. pressure lines, low-pressure side fairly cold, cold. temperature. State in sight glass. Bubbles flow continu- The bubbles are seen Almost transparent, No bubbles can be seen, ously. Bubbles will at intervals of 1-2 Bubbles may appear when disappear and something seconds. engine speed is raised and like mist will flow when lowered. refrigerant is nearly gone. No clear difference exists between these two condi- tions,

AC256 AC257 AC258

Pressure of system. High-pressure side is ab- Both pressures on high Both pressures on high Both pressures on high narmally low. and low-pressure sides are and low-pressure sides are and low-pressure sides are slightly law. normal. abnormally high, Repair,

Check for gas leakage, re-

Stop compressor im- Discharge refrigerant fram mediately and conduct pair as required, replenish service valve of low an overall check, and charge system. pressure side.

a.

The bubbles seen through the sight glass are

exceeds 20°C (68°F). In higher temperature

influenced by the ambient temperature. Since

the bubbles are easy to show up.

the bubbles are hard to show up in compara-

When the screen in the receiver drier is clog

tively low temperatures below 20°C (68°F), it

ged, the bubbles will appear even if the amount

is possible that a slightly larger amount of re-

or refrigerant is normal. In this case, the outlet

frigerant would be filled, if supplied according

side pipe of the receiver drier becomes con-

to the sight glass. Recheck the amount when it

siderably cold.

HA-26