Workshop Manuals Factory service & repair Nissan and Datsun
01 cover02 A (intro)03 B (CA18DET/ECCS)04 C (driveline)05 D (body & frame)06 E (interior electric)07 F (misc. codes)08 manual notes09 Front cover10 CONTENTS11 GI General information12 MA maintenance13 EM engine mechanical14 LC lubrication & cooling15 EF &EC engine fuel & emission control system16 FE engine control fuel & exhaust systems17 CL clutch18 MT manual transmission19 AT automatic transmission20 PD prop shaft & diff carrier21 FA front axle & suspension22 RA rear axle & suspension23 BR brake system24 ST steering25 BF body26 HA heater & aircon27 EL electrical system
Nissan and Datsun Nissan 180SX S13 1989 Workshop Manual26 · HA heater & aircon
26 · General

DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

Make
Nissan and Datsun
Model
180SX Nissan 180SX S13 1989 Workshop Manual
Section
General › DISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual
HA heater & airconDISCHARGING, EVACUATING, CHARGING AND CHECKING - Nissan 180SX S13 Workshop Manual

DISCHARGING, EVACUATING, CHARGING AND CHECKING

DISCHARGING, EVACUATING, CHARGING AND CHECKING

Checking Refrigerant Leaks

Nominal sensitivity:

ELECTRIC LEAK DETECTOR

The leak detector is a delicate device that detects small amounts of halogen. To use the device properly, read the manufacturer's manuals. Also perform the specified maintenance and inspections.

SHA?733A

GENERAL PRECAUTIONS FOR HANDLING LEAK

UNION TYPE

DETECTOR Place the probe on connection fitting and wait for 5 seconds or more. To check cooling unit, wait for 10 seconds or more. [Hy Keep the probe as still as possible for one more minute. — —|

RHA279 When testing single-bolt flange, place the probe on the

PLATE TYPE

opposite side of the fitting. a N

al ln

RHA2Z80

MEASUREMENT STANDARD

if any leak is noted with a detector having a nominal sensitivity of 15 to 25 g (6.53 to 0.88 oz)/year, that leak must be repaired. @ The nominal sensitivity of the detector is determined under the assumption that all the leaking gas is collected by the detector. Accordingly, the quantity of gas actually leaking can amount to five to ten times the indicated value. Generally speaking, leakage of 150 to 200 g (5.29 to 7.05 oz) of refrigerant can cause insufficient cooling. @ Oil deposited during assembling must be wiped off before inspection. Refrigerant easily dissolves in oil, and the pres- ence of oil can cause an error in measurement. This precaution is important when checking a used car for refrigerant leakage. @® if oil is noted at or around connections, it indicates that refrigerant is leaking.

HA-27

Parts & tools for this job For Nissan 180SX

As an Amazon Associate we earn from qualifying purchases.