Inspection
- Make
- Rover
- Model
- 600 Rover 600 Repair Manual - Volumes 1 and 2 - 2nd Edition
- Section
- Repairs › Inspection
Engine management system – PGM-FiInspection
Inspection
WARNING: Do not smoke during this procedure. Keep any open flame away from your work area.
- Warm up and calibrate the CO meter according to the meter manufacturer's instructions.
- Start the engine and warm it up to normal operating temperature (the radiator fan comes ON twice).
- Connect a tachometer.
- Check idle speed and adjust the idle speed, if necessary.
- Start the engine and hold engine speed at 2,500 – 3,000 rpm for 2 minutes.
- Check idle CO with the headlights, blower fan, rear window screen demister, radiator fan, and air conditioner OFF. The CO meter should indicate 0.2% maximum.
POSITIVE CRANKCASE VENTILATION (PCV)
Inspection
- A Breather hose
- B PCV hose
- C PCV valve
- Check the PCV hoses and connections for leaks and clogging.
- At idle, make sure there is a clicking sound from the PCV valve when the hose between PCV valve and intake manifold is lightly clamped with your fingers or pliers as shown by the arrow.
- If there is no clicking sound, check the PCV valve grommet for cracks or damage. If the grommet is OK, replace the PCV valve and recheck.
Parts & tools for this job For Rover 600
- PARTEngine gasket setSearch: Rover 600 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set