SERVICING PRECAUTIONS
Care should be taken when handling components of the refrigeration system. Units must not be lifted by their hoses, pipes or capillary lines. Hoses and lines must not be subjected to any twist or stress. Ensure that hoses are positioned in their correct run before fully tightening the couplings, and ensure that all clips and supports are used. Torque wrenches of the correct type must be used when tightening refrigerant connections to the stated value. An additional backing spanner must be used to hold the union to prevent twisting of the pipe.
Before connecting any hose or pipe ensure that refrigerant oil is applied to the seat of the new ’0’ ring seal but not to the threads.
Check the oil trap for the amount of oil lost.
All protective plugs must be left in place until immediately prior to connection.
The receiver/drier contains dessicant which absorbs moisture. It must be positively sealed at all times.
CAUTION: Whenever the refrigerant system is opened, the receiver/drier must be renewed immediately before evacuating and recharging the system.
Use alcohol and a clean cloth to clean dirty connections.
Ensure that all new parts fitted are marked for use with R134a.
Refrigerant oil
Use an approved refrigerant lubricating oil:
Nippondenso Densoil 8
CAUTION: Do not use any other type of refrigerant oil.
Refrigerant oil is hydroscopic and must not be stored for long periods. Do not pour unused oil back into the container.
When renewing system components, add the following quantities of refrigerant oil.
| Condenser | 30cm3 |
| Evaporator | 60cm3 |
| Pipe or hose | 10cm3 |
| Receiver / drier | 10cm3 |
When a fitting a new compressor, refrigerant oil needs to be removed and a measured quantity added prior to fitting.
CAUTION: A new compressor is sealed and pressurised with Nitrogen gas, slowly (to avoid oil loss) release the sealing cap, gas pressure should be heard to release as the seal is broken.
NOTE: A new compressor should always have its sealing caps in place and they must not be removed until immediately prior to fitting.
Rapid refrigerant discharge
When the air conditioning system is involved in accident damage and the circuit is punctured, the refrigerant is discharged rapidly. The rapid discharge of refrigerant will also result in the loss of most of the oil from the system. The compressor must be removed and all the remaining oil drained and the compressor refilled as follows:
- Drain all the oil from the inlet port, rotate the clutch plate (not the pulley). Fill the compressor with the following amount of new oil:
KV6 models = 100 æ 20 cm3
Diesel models = 100 æ 20 cm3
- Plug the inlet and outlet ports.