Dpf input temperature sensor operation check
- Make
- Fiat
- Model
- 500 Factory Service Manual
- Year
- 2007–2024
- Section
- Emission control system › Dpf input temperature sensor operation check
‹ Prev Differential pressure sensor operation checkNext › Check the operation of the lambda sensor heater
EngineDpf input temperature sensor operation check
DPF INPUT TEMPERATURE SENSOR OPERATION CHECK
POWER SUPPLY CHECK
- Connect the positive probe of an Examiner in Voltmeter mode to terminal 1 of the temperature sensor and the negative probe to an earth point
- Turn the key to the MAR position
- Read a voltage of around 5 Volts
| Pin | Function |
|---|---|
| 1 | 5 Volts |
| 2 | earth |
SENSOR RESISTANCE CHECK
- Disconnect the wiring connector from the sensor
- Connect an Examiner in Ohmmeter mode to the sensor terminals
- Check the resistance is similar to the attached table
| TEMPERATURE (C °) | RESISTANCE (Ohm) |
|---|---|
| -40 | 169,7 |
| -20 | 185,1 |
| 0 | 200,5 |
| 25 | 219,6 |
| 50 | 238,5 |
| 100 | 275,9 |
| 150 | 312,7 |
| 200 | 349,0 |
| 250 | 384,6 |
| 300 | 419,7 |
| 400 | 488,1 |
| 500 | 554,1 |
| 600 | 617,8 |
| 700 | 679,2 |
| 800 | 738,2 |
| 900 | 794,9 |
| 1000 | 849,2 |
‹ Prev Differential pressure sensor operation checkNext › Check the operation of the lambda sensor heater
Parts & tools for this job For 2007 Fiat 500
- TOOLOBD2 scannerSearch: OBD2 scanner
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBack-probe test leadsSearch: back probe test leads
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.