Checking winding resistance
- Make
- Fiat
- Model
- Bravo /Brava (182) Factory Service Manual
- Year
- 1995–2001
- Section
- Fuel system (98 range, 1581 16v) › Checking winding resistance
Checking winding resistance
Primary circuit (A cylinders 1-4, B cylinders 2-3)
Place the leads of an ohmmeter in contact with the positive terminal (central pin) and negative terminal (pin 1 for circuit A and pin 2 for circuit B).
The resistance of the primary circuit read on the instrument must be between 0.44 and 0.53 ohm at 23°C.
Secondary circuit (C cylinders 1-4, D cylinders 2-3)
Connect the leads of an ohmmeter between the two high-tension output terminals.
The resistance of the secondary circuit read on the instrument must be between 4500 and 5500 ohm at 23 °C.
Recovery
Inhibition of the injectors corresponding to the cylinders where there is no ignition.
Open-loop check of mixture strength.
If there is a short circuit to positive, the command in progress is disabled and there is a retry.
In the case of open circuit or short circuit to earth, a fixed charge time is assumed.
Removing refitting
- Disconnect the high-tension cables and wiring connector from the ignition coils assembly.
- Undo the bolts (arrowed) and remove the ignition coils.
Parts & tools for this job For 1995 Fiat Bravo
- PARTFuel filterSearch: Fiat Bravo 1995 fuel filter
- TOOLFuel pressure test kitSearch: fuel pressure test kit
- TOOLFuel line disconnect toolSearch: fuel line disconnect tool