01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

P0110 - debimeter air temperature signal

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Examiner - electronic diesel management › P0110 - debimeter air temperature signal
Fault diagnosisP0110 - debimeter air temperature signal

P0110 - DEBIMETER AIR TEMPERATURE SIGNAL

1.9 JTD 8v, 1.9 JTD 16v, 2.4 JTD 20v

The diagnostic equipment signals: Error P0110 (Air flow meter temperature signal)

This error is detected if the junction unit inlet voltage (Pin 53) is greater than 4.95 V (positive short circuit) (detail "Beyond the upper limit" or less than 0.05 V (short circuit to earth or break in the circuit) (detail "Below the lower limit"). In this case the junction unit replacement value is 40 °C.

1SUPERCHARGING TEMPERATURE SENSOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check that the supercharging temperature sensor is working properly, following the instructions in the

See Test 1064BD SUPERCHARGING TEMPERATURE CHECK

End of diagnosis