Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

P0111 - debimeter air temperature signal

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Examiner - electronic diesel management › P0111 - debimeter air temperature signal
Fault diagnosisP0111 - debimeter air temperature signal

P0111 - DEBIMETER AIR TEMPERATURE SIGNAL

1.9 JTD 8v, 1.9 JTD 16v, 2.4 JTD 20v

The diagnostic equipment signals: Error P0111 (flow meter air temp. signal).

This error is detected if there is interference with the signal for the sensor at Pin 37 of the electronic control module (detail "general electrical fault") or if there is a short circuit to positive (detail "beyond the upper limit") or to earth (detail "below the lower limit") in the circuit connected to Pin 37 of the control unit. In the case of short circuits, the control unit takes 25 °C as the replacement value.

1FLOW METER OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check that the flow meter is working properly by carrying out the

See Test 1060GS CHECK ON FLOW METER OPERATION

End of diagnosis

Parts & tools for this job For 2005 Fiat Croma

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.