01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Croma Factory Service Manual (2005-2010)22 · Fault diagnosis
22 · Diagnostics

P0697 - sensor power supply 3

Make
Fiat
Model
Croma Factory Service Manual
Year
2005–2010
Section
Examiner - electronic diesel management › P0697 - sensor power supply 3
Fault diagnosisP0697 - sensor power supply 3

P0697 - SENSOR POWER SUPPLY 3

1.9 JTD 8v, 1.9 JTD 16v, 2.4 JTD 20v

The diagnostic equipment signals: Error P0697 (Sensor power supply 3).

This error is detected if there is a short circuit to positive (detail "beyond the upper limit") or a short circuit to earth or a brek (detail "below the lower limit") in the circuit connected to Pin 22, or 44 of the junction unit.

1Junction unit connections checkALL OKPROBLEMS ENCOUNTEREDACTION

Check that the engine management control unit connections are correct by carrying out the test

See Test 1060GP CHECK ON ENGINE MANAGEMENT CONTROL UNIT SENSOR CONNECTIONS 3

End of diagnosis