Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Bravo Factory Service Manual (2007-2014)22 · Fault diagnosis
22 · Diagnostics

Milometer/trip meter flashing

Make
Fiat
Model
Bravo Factory Service Manual
Year
2007–2014
Section
Instrument panel › Milometer/trip meter flashing
Fault diagnosisMilometer/trip meter flashing

MILOMETER/TRIP METER FLASHING

At the end of the check, the mileometer/trip counter on the panel begins to flash

1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect an Examiner and check that the Instrument Panel Node is aligned in Control Unit Test, Other System Group and Proxy Alignment Procedure modes.Move on to Step 81. Impossible to carry out Proxy alignment1. Move on to Step 2
2. Alignment not carried out2. Carry out Proxy alignment
2CHECK INSTRUMENT PANELALL OKPROBLEMS ENCOUNTEREDACTION
Check that the installed panel reflects the vehicle specifications (it is not possible to install the panel of a petrol version on a diesel version)Move on to Step 3Panel does not correspond to the vehicle specification

Replace instrument panel

Op. 5560B10 CONTROL PANEL - R+R

3CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner diagnostic equipment and check, in Instrument Panel Node mode, that there are no errors and that the parameters are present.Move on to Step 81. Impossible to connect to the NQS1. Move on to Step 4
2. Presence of errors2. Move on to Step 7
4ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the electricity supply to the Instrument Panel Node is correct.

See E4010 INSTRUMENT PANEL

Move on to Step 5Fault in positive electrical supply and/or earthRenew and/or replace the defective component (in the case of a fuse, find out what caused it to blow).
5ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the Instrument Panel Node electrical wiring/connections, in particular that each pin is correctly connected and inserted in its seatMove on to Step 6Electrical wiring and/or connections not workingRestore the damaged electrical wiring and/or connections
6CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Use an Examiner to check the possibility of connection to the Instrument Panel NodeMove on to Step 7Impossible to connect with the control unit

Replace the instrument panel

Op. 5560B10 CONTROL PANEL - R+R

7ERROR CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check for the presence of one or more of the following errors using the Examiner in Instrument Panel Node mode:

  • CAN line
  • EEPROM memory
Move on to Step 81. Detected "no additional information" and/or "BUS off"1. Continue as described by the diagnostic equipment
2. Fault in EEPROM memory

2. Replace the instrument panel

Op. 5560B10 CONTROL PANEL - R+R

8ACTIVE DIAGNOSIS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Use the Examiner to check the Autotest function is correctly activated in Active Diagnosis modeMove on to Step 9The function in question is not controlled by Active Diagnosis

Replace the instrument panel

Op. 5560B10 CONTROL PANEL - R+R

9CORRECT OPERATION CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present.End of diagnosis

Parts & tools for this job For 2007 Fiat Bravo

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.