01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Bravo Factory Service Manual (2007-2014)22 · Fault diagnosis
22 · Diagnostics

Parking brake failure warning light on

Make
Fiat
Model
Bravo Factory Service Manual
Year
2007–2014
Section
Instrument panel › Parking brake failure warning light on
Fault diagnosisParking brake failure warning light on

PARKING BRAKE FAILURE WARNING LIGHT ON

The brake fluid warning light remains on with the handbrake released.

The (negative) brake fluid level signal is sent by the sensor to the Body Computer Node which makes it available via the B-CAN to the Instrument Panel Node.

The Instrument Panel Node lights up the dedicated warning light if the brake fluid level is too low.

TEST RESULTS
0PRELIMINARY CHECKSALL OKPROBLEMS ENCOUNTEREDACTION

Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:

- No control units inactive

- No faulty control units

- No control units with faulty CAN line

Move on to Step 5

1. Fault in CAN

2. Communication with the Body Computer impossible

1. Continue following the instructions given by the diagnostic equipment

2. Move on to Step 2

1CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeMove on to Step 4

1.The parameter is not plausible

2.Impossible to connect to the Body Computer control unit

1.Replace Body Computer

Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.

2. Move on to Step 2

2ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Body Computer Node is correct.Move on to Step 3Fault in positive electrical supply and/or earth.Replace defective component (in the case of a fuse, find out what caused it to blow).
3BRAKE FLUID LEVEL CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check that the brake fluid level is not lowMove on to Step 9Insufficient brake fluid levelMove on to Step 4
4BRAKE FLUID LEVEL TOP UPALL OKPROBLEMS ENCOUNTEREDACTION
Top up the brake fluid level and check that the warning light goes outEnd of diagnosisThe warning light does not go outMove on to Step 6
5CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the diagnostic equipment connected, check that there are no CAN faults at the BRAKE NODEMove on to Step 6Fault at C-CANMove on to Step 11
6ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Disconnect the connector from the oil level sensor and check that it is working properly

See E4010 INSTRUMENT PANEL

Move on to Step 7Brake fluid level sensor defective

Replace the brake fluid level sensor

Op. 3330C30 BRAKE FLUID RESERVOIR - R + R AND WASH INSIDE

7ELECTRICAL SYSTEM CHECKALL OKPROBLEMS ENCOUNTEREDACTION

Check the continuity of the cable from the connector to the Body Computer

See E4010 INSTRUMENT PANEL

Move on to Step 8Lead broken

Restore the correct connection

See E4010 INSTRUMENT PANEL

8CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Connect the Examiner or keep it connected and check the operation of the brake fluid level warning light in active diagnosis at the Instrument Panel NodeMove on to Step 11The warning light does not flash

Replace the instrument panel

Op. 5560B10 CONTROL PANEL - R+R

9ELECTRICAL POWER SUPPLY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electricity supply to the Instrument Panel Node is correct.Move on to Step 10Fault in positive electrical supply and/or earth.Replace defective component (in the case of a fuse, find out what caused it to blow).
10ELECTRICAL CONNECTIONS CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the electrical connections between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected.Move on to Step 11Electrical connections not operational.Refit the electrical connections correctly.
11CHECK USING DIAGNOSTIC EQUIPMENTALL OKPROBLEMS ENCOUNTEREDACTION
Keeping the Examiner connected, check the plausibility of the brake fluid level parameter at the Body Computer NodeEnd of diagnosisThe parameter is not plausible

Replace Body Computer

Op. 5505A35 MAIN BODY COMPUTER/JUNCTION UNIT - R.R.