01 Introduction02 General information03 General data04 Identification numbers05 Torque wrench settings06 Lifting and towing07 Capacities, fluids and lubricants08 Maintenance09 Engine - Td510 Engine - V811 Emission control - Td512 Emission control - V813 Engine management system - Td514 Engine management system - V815 Fuel delivery system - Td516 Fuel delivery system - V817 Cooling system - Td518 Cooling system - V819 Manifolds and exhaust systems - Td520 Manifolds and exhaust systems - V821 Clutch - Td522 Clutch - V823 Manual gearbox - R38024 Transfer box - LT230SE25 Automatic gearbox - ZF4HP22/2426 Propeller shafts27 Rear axle28 Front axle29 Steering30 Front suspension31 Rear suspension32 Brakes33 Restraint systems34 Doors35 Exterior fittings36 Interior trim components37 Screens38 Seats39 Sunroof40 Chassis and body dimensions41 Panel repairs42 Body sealing materials43 Corrosion prevention and sealing44 Painting45 Heating and ventilation46 Air conditioning47 Wipers and washers48 Charging and starting49 Lighting50 Body control unit51 Alarm system and horn52 Windows53 In car entertainment54 Harnesses55 Driving aids56 Navigation system57 Instruments
Land Rover Discovery II (UK)45 · Heating and ventilation
45 · Heating & A/C

Heating and ventilation (Operation): Description and operation

Make
Land Rover
Model
Discovery II (UK)
Section
Description and operation › Operation
Heating and ventilationOperation

Operation

Air distribution

Turning the distribution knob on the control panel turns the control flaps in the heater assembly to direct air to the corresponding fascia and footwell outlets.

Air temperature

Turning the LH or RH temperature knob on the control panel turns the related blend flaps in the heater assembly. The blend flaps vary the proportion of air going through the cold air bypass and the heater matrix. The proportion varies, between full bypass no heat and no bypass full heat, to correspond with the position of the temperature knob.

Blower speed

The blower can be selected off or to run at one of four speeds. While the ignition is on, when the blower switch is set to positions 1, 2, 3, or 4, ignition power energises the blower relay, which supplies battery power to the blower. At switch positions 1, 2 and 3, the blower switch also connects the blower to different earth paths through the resistor pack, to produce corresponding differences of blower operating voltage and speed. At position 4, the blower switch connects an earth direct to the blower, bypassing the resistor pack, and full battery voltage drives the blower at maximum speed.

Fresh/Recirculated inlet air

When the recirculated air switch is latched in, the amber indicator LED in the switch illuminates and an earth is connected to the recirculated air side of the fresh/recirculated air servo motor. The fresh/recirculated air servo motor then turns the control flaps in the air inlet duct to close the fresh air inlet and open the recirculated air inlets.

When the latch of the recirculated air switch is released, the amber indicator LED in the switch extinguishes and the earth is switched from the recirculated air side to the fresh air side of the fresh/recirculated air servo motor. The fresh/ recirculated air servo motor then turns the control flaps in the air inlet duct to open the fresh air inlet and close the recirculated air inlets.

FBH system (where fitted)

The FBH system operates only while the engine is running and the ambient temperature is less than 5 °C (41 °F). With the engine running and the ambient temperature below 5 °C (41 °F), the air temperature sensor connects the alternator power supply to the ECU in the FBH unit. On receipt of the alternator power supply, the ECU starts the circulation pump and, depending on the input from the temperature sensor in the heat exchanger, enters either a standby or active mode of operation. If the heat exchanger casing temperature is 65 °C (149 °F) or above, the ECU enters a standby mode of operation. If the heat exchanger casing temperature is below 65 °C (149 °F), the ECU enters an active mode of operation. In the standby mode, the ECU monitors the heat exchanger casing temperature and enters the active mode if it drops below 65 °C (149 °F). In the active mode, the ECU initiates a start sequence and then operates the system at full or part load combustion to provide the required heat input to the coolant.

Start sequence At the beginning of the start sequence the ECU energises the glow plug function of the glow plug/flame sensor, to preheat the combustion chamber, and starts the combustion air fan at slow speed. After 30 seconds, the ECU energises the FBH fuel pump at the starting sequence speed. The fuel delivered by the FBH fuel pump evaporates in the combustion chamber, mixes with air from the combustion air fan and is ignited by the glow plug/flame sensor. The ECU then progressively increases the speed of the FBH fuel pump and the combustion air fan to either part or full load speed, as required by the system. Once full or part load speed is achieved, the ECU switches the glow plug/flame sensor from the glow plug function to the flame sensing function to monitor combustion. From the beginning of the start sequence to stable combustion takes approximately 90 seconds for a start to part load combustion and 150 seconds for a start to full load combustion.