Cooler - gearbox fluid
- Make
- MG
- Model
- MGF Factory Workshop Manual
- Year
- 1995–2000
- Section
- Repairs › Cooler - gearbox fluid
Automatic gearbox - EM-CVTCooler - gearbox fluid
COOLER - GEARBOX FLUID
Service repair no - 44.24.10
Remove
- Remove bonnet locking platform. See BODY, Exterior fittings.
- Position container underneath gearbox fluid cooler connections to collect any spillage.
- Remove 2 bolts securing cooler pipe connections to fluid cooler.
- Release connections from cooler and discard ’O’ rings.
CAUTION: Plug the connections.
- Remove 2 bolts securing cooler to body and remove cooler.
Refit
- Clean fluid cooler and pipe connections.
- Fit fluid cooler and secure with bolts.
- Using new ’O’ rings connect pipes to cooler and tighten bolts to 14 Nm.
- Fit bonnet locking platform. See BODY, Exterior fittings.
- Top-up gearbox fluid level. See MAINTENANCE.
Parts & tools for this job For 1995 MG MGF
- PARTTransmission filter kitSearch: MG MGF 1995 transmission filter kit
- FLUIDAutomatic transmission fluidSearch: MG automatic transmission fluid
- TOOLFluid transfer pumpSearch: fluid transfer pump