INSTRUMENT PANEL NOT WORKING
With the ignition ON, some of the warning lights are not timed and the instruments are not working with the engine running.
| 0 | PRELIMINARY CHECKS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
|---|---|---|---|---|
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:
| Move on to Step 1 | 1. Fault on CAN network | 1. Continue following the instructions for the diagnostic equipment | |
| 2. Communication impossible with the Body Computer | 2. Move on to Step 2 | |||
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Using an Examiner check, in Instrument Panel mode, that there are no errors and that the parameters are present | Move on to Step 4 | 1. Presence of errors | 1. Continue following the instructions on the diagnostic instrument | |
| 2. Communication impossible with the instrument panel | 2. Move on to Step 3 | |||
| 2 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the electricity supply to the Instrument Panel Node is correct by carrying out the test | Move on to Step 3 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 3 | CHECK ELECTRICAL CONNECTIONS | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the wiring between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected. | Move on to Step 4 | Electrical connections not operational | Renew the damaged electrical connections | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Using an Examiner check, in Body Computer Node mode, that there are no errors. | Move on to Step 7 | 1. Impossible to connect to the Body Computer control unit. | 1. Move on to Step 5 | |
| 2. Presence of errors | 2. Continue by following the instructions on the diagnostic instrument | |||
| 5 | ELECTRICAL POWER SUPPLY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the electricity supply to the Body Computer Node is correct. | Move on to Step 6 | Fault in positive electrical supply and/or earth | Replace defective component (in the case of a fuse, find out what caused it to blow) | |
| 6 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Use an Examiner to check the possibility of connection to the Body Computer Node. | Move on to Step 7 | Impossible to connect to the Body Computer control unit. | Replace Body Computer | |
| 7 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | End of diagnosis | The fault persists | Replace the Instrument Panel |
‹ Prev Instrument lights dimmer not workingNext › Mil warning light not working (remains off before starting)
Parts & tools for this job For 2005 Fiat Croma
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Fiat Croma
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.