| 1. | Manual override - face level vents | |
| 2. | Manual override - face and foot level vents | |
| 3. | Manual override - foot level vents | |
| 4. | Manual override - foot and screen vents | |
| 5. | Manual override - defrost/demist screen vents | |
| 6. | Heated rear window | |
| 7 | AUTO | Selects full control of all functions, blower speed, temperature control and air distribution, and will override previous settings. |
| 8 | OFF | Switches the computer display off, selects recirculation mode to prevent air entering interior, switches the blower and compressor off. |
| 9 | Manual override - recirculation mode. | |
| 10 | EXT | Select exterior temperature display (replaces the setpoint display). In conjunction with switch 11 allows °C or °F to be displayed. |
| 11 | - + | SETPOINT rocker switch increases or decreases the system setpoint as shown in display. A subsidiary function in conjunction with switch 10 allows choice of display units in °C or °F. |
| 12 | Manual overrides blower speed, provides three fixed speeds and off. The blower will not switch off when the compressor is operating. | |
| 13 | ECON | Manual override of computer selected compressor operation and switches the compressor off. With the compressor off, the blower switch can switch the blower off. |
| 14 | TEMPERAT- URE DISPLAY | The display can show the following: A. 19 to 29 °C, 66 to 85 °F - Setpoint. B. HI or L0 - maximum heating or cooling C. -20 to + 55 °C, -4 to 131 °F - Exterior temperature. In the rare event of the exterior temperature being below -20 °C, -4 °F or above 55 °C, 131 °F the display will show LO or HI respectively. D. Er - system hardware fault detected at ignition switch on. |
| 15 | BLOWER SPEED | Manual override, bar display: SLOW - one bar. NORMAL - two bars, FAST - three bars. The blower symbol is displayed when the pack is switched on. Pressing the switch when three bars are displayed, switches the blower off. The blower will not switch off when the compressor is operating. The display does not show blower speed in AUTO mode. |