Inlet manifold gasket - ’k’ series (page 2 of 4)
- Make
- Rover
- Model
- 400 Workshop Manual
- Year
- 1995–2000
- Section
- Repairs
Manifold & exhaust systemsInlet manifold gasket - ’k’ series · page 2 of 4
- Loosen clip and disconnect air intake hose from air cleaner.
- Release clip and disconnect purge hose from inlet manifold.
- Release clip and disconnect breather hose from throttle body.
- Disconnect multiplug from throttle position sensor.
- Release clip and disconnect hose from stepper motor.
- Release throttle cable from clips on manifold.
- Remove 4 bolts securing throttle body to inlet manifold, remove throttle body and place aside.
- Remove and discard ’O’ ring.
- Disconnect multiplug from stepper motor.
- Release distributor h.t. lead from manifold bracket.
- Disconnect breather hose from inlet manifold.
- Depress plastic collar and disconnect brake servo hose from inlet manifold.
- Disconnect ECM vacuum hose from manifold.
- Release clip and disconnect fuel return hose from fuel rail. Release hose from 2 clips on manifold.
CAUTION: Plug the connections.
Parts & tools for this job For 1995 Rover 400
- PARTExhaust gasketSearch: Rover 400 1995 exhaust gasket
- TOOLPenetrating oilSearch: penetrating oil
- TOOLOBD2 scannerSearch: OBD2 scanner