| Start the engine and idle it. Access LONG FT1 PID. Measure LONG FT1 PID at idle. Is PID value normal? (See PCM INSPECTION [LF] .) | Less than specification (too rich): Greater than specification (too lean): | • Inspect EVAP control system. • If system is normal, go to Step 14. • Inspect for air leakage at intake-air system components. • If system is normal, go to the next step. | |
| 15 | Disconnect the vacuum hose between the purge solenoid valve and the intake manifold from purge solenoid valve side. Plug opening end of vacuum hose. Start the engine. Does the engine condition improve? | Yes | Check if purge solenoid valve is stuck open mechanically. Inspect EVAP control system. |
| No | Go to the next step. | ||
| 16 | Remove and shake the PCV valve. Does the PCV valve rattle? | Yes | Go to the next step. |
| No | Replace the PCV valve. | ||
| 17 | Visually inspect the exhaust system part. Is there any deformed exhaust system part? | Yes | Replace the suspected part. |
| No | Go to the next step. | ||
| 18 | Visually inspect the CMP sensor and teeth of camshaft. Are the CMP sensor and teeth of camshaft normal? | Yes | Go to the next step. |
| No | Replace the malfunctioning part. | ||
| 19 | Inspect the engine condition while tapping EGR valve housing. Does the engine condition improve? | Yes | Replace the EGR valve. |
| No | Go to the next step. |