REFRIGERANT RECOVERY, RECYCLING AND RECHARGING

82-1

AIR CONDITIONING

REFRIGERANT RECOVERY, RECYCLING AND RECHARGING

Refrigerant recovery - recycling and 
recharge

$% 82.30.02

Refrigerant recovery

WARNING: Servicing must only be carried 
out by personnel familiar with both the 
vehicle system and the charging and testing 
equipment. All operations must be carried 
out in a well ventilated area away from open 
flame and heat sources.

1. Remove dust caps from high and low pressure 

connectors.

2. Connect high and low pressure hoses to 

appropriate connections.

3. Open valves on connectors.
4. Turn valves on refrigerant station to correct 

positions.

5. Turn process switch to correct position.
6. Turn main switch to 'ON'.
7. Allow station to recover refrigerant from 

system.

WARNING: Refrigerant must always be 
recycled before re-use to ensure that the 
purity of the refrigerant is high enough for 
safe use in the air conditioning system. 
Recycling should always be carried out with 
equipment which is in compliance with SAE 
J2210. Other equipment may not recycle 
refrigerant to the required level of purity. A 
R134a Refrigerant Recovery Recycling 
Recharging Station must not be used with 
any other type of refrigerant. Refrigerant 
R134a from domestic and commercial 
sources must not be used in motor vehicle 
air conditioning systems. 

8. Close valves on refrigerant station.

9. Turn main switch to 'OFF'.

10. Close valves on connectors.
11. Disconnect high and low pressure connectors.
12. Fit dust caps to connectors.
13. Open tap at rear of station to drain refrigerant 

oil.

14. Measure and record quantity of refrigerant oil 

recovered from system.

15. Close tap at rear of station.

Evacuation

1. Remove dust caps from high and low pressure 

connectors.

2. Connect high and low pressure hoses to 

appropriate connections.

3. Open valves on connectors.
4. Turn valves on refrigerant station to correct 

positions.

5. Turn Process switch to correct position.
6. Turn main switch to 'ON'.
7. Allow station to evacuate system.

Recharging

CAUTION: The system must be evacuated 
immediately before recharging 
commences. Delay between evacuation and 
recharging is not permitted.

1. Close valves on refrigerant station.
2. Close valve on oil charger.
3. Disconnect yellow hose from refrigerant 

station.

4. Remove lid from oil charger.
5. Pour correct quantity of refrigerant oil into oil 

charger. 
 

 + 

 GENERAL DATA, Air Conditioning.

6. Fit lid to oil charger.
7. Connect yellow hose to refrigerant station.
8. Open valve on oil charger.
9. Move pointer on refrigerant gauge to mark 

position of refrigerant drop.

10. Slowly open correct valve on refrigerant station 

and allow vacuum to pull refrigerant into 
system.

11. Close valve on refrigerant station when correct 

amount of refrigerant has been drawn into air 
conditioning system. 
 

 + 

 GENERAL DATA, Air Conditioning.

12. Turn main switch to 'OFF'.
13. Close valves on connectors.
14. Disconnect high and low pressure connectors.
15. Fit dust caps to connectors.

M82 0728