DISPLAY DOES NOT SHOW RANGE ON TRIP MODULE
With the key ON, the fuel consumption gauge on the display (one of the displays on the TRIP COMPUTER module) is not operational.
N.B: The display shows the range processed by the instrument panel node on the basis of information received from the body computer node (distance and fuel level as a percentage) and from the engine management node (consumption) made available to the instrument panel node via the B-CAN and C-CAN respectively. This data is then adjusted proportionally according to the tank capacity programmed at the EOL.
In the absence of speed information (from the Brake Node) or instantaneous fuel consumption data (from the Engine Control Node), the fuel consumption data will be replaced by the reading "----"
| Test results | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems encountered | Operation |
|---|---|---|---|---|
Interview the customer to check that the TRIP function has not been recently reset Check that the fuel gauge shows a sufficient quantity of fuel | Move on to Step 1 | 1. One of the TRIP COMPUTER functions has been reset 2. Insufficient amount of fuel | 1. The display reading will be "----" until sufficient distance has been covered to allow fuel consumption to be evaluated: if the value is not displayed after a few kilometres, continue to Step 1 2.Refill with a sufficient amount of fuel | |
| 1 | CAN CHECK | All OK | Problems encountered | Operation |
Connect an EXAMINER and check the following on CAN NETWORK INFORMATION:
| Move on to Step 2 | 1. Fault on CAN network 2. Communication with the Body Computer impossible | 1. Continue following the instructions given by the diagnostic equipment 2. Move on to Step 8 | |
| 2 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Keeping the diagnostic instrument connected, check the following on the BRAKE NODE:
| Move on to Step 3 | 1. System/components faulty 2. Fault on C-CAN network | 1. Continue following the instructions given by the diagnostic equipment 2. Move on to Step 9 | |
| 3 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Keeping the diagnostic instrument connected, check the following on the ENGINE CONTROL NODE:
| Move on to Step 4 | 1. System/components faulty 2. Fault on C-CAN network | 1. Continue following the instructions given by the diagnostic equipment 2. Move on to Step 9 | |
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
Keeping the diagnostic instrument connected, check the following on the INSTRUMENT PANEL NODE:
| Move on to Step 5 | 1. System/components faulty 2. Fault on C-CAN network | 1. Continue following the instructions given by the diagnostic equipment 2. Move on to Step 9 | |
| 5 | ACTIVE DIAGNOSIS CHECK | All OK | Problems encountered | Operation |
| With the Examiner in Instrument Panel Node mode check that all segments of the LCD module are correctly activated in Active Diagnosis. | Move on to Step 7 | 1. One or more segments do not activate 2. Communication with the instrument panel impossible | 1. Replace the Instrument Panel Op. 5560B10 CONTROL PANEL - R+R 2. Move on to Step 6 | |
| 6 | ELECTRICAL CONNECTIONS CHECK | All OK | Problems encountered | Operation |
| Check the electrical connections between the Body Computer and the Instrument Panel. In particular, check that each individual pin is properly connected. | Move on to Step 5 | Electrical connections not operational | Renew the damaged electrical connections. | |
| 7 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Using an Examiner check, in Body Computer Node mode, that there are no errors. | Move on to Step 9 | 1. Impossible to connect to the Body Computer control unit 2. Presence of errors | 1. Move on to Step 8 2. Continue by following the instructions on the diagnostic instrument | |
| 8 | ELECTRICAL POWER SUPPLY CHECK | All OK | Problems encountered | Operation |
| Check the electricity supply to the Body Computer Node is correct. | Move on to Step 9 | Fault in positive electrical supply and/or earth. | Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 9 | CHECK USING DIAGNOSTIC EQUIPMENT | All OK | Problems encountered | Operation |
| Use an Examiner to check the possibility of connection to the Body Computer Node | End of diagnosis | Impossible to connect to the Body Computer control unit. | Replace Body Computer | |